Renal Technician Program · Examination

End-of-Course Examination

30 questions drawn at random from all 12 modules of the Hemodialysis Center Biomedical Technician series.

PublishedNailathalaGipatikPepalwal: Audience: Biomedical equipment technicians working in or for hemodialysis centers · chief technicians, head nurses, and medical directors Read timeOras ng pagbasaOras sa pagbasaOras ning pamamasa:
Renal Care Academy›Hemodialysis Center Biomedical Technician›End-of-course examination

How this examination works

This examination covers the whole Hemodialysis Center Biomedical Technician series. Each sitting draws 30 questions at random from a bank of 100, in random order, with the answer choices shuffled. Choose the single best answer for each question, then select Check answers.

When to take itAfter you have finished every module and reviewed the questions you missed.
How to take itIn one sitting, without notes. Allow about one minute per question.
Proposed pass mark24 of 30 best answers (80 percent). Your trainer may set a different mark.
If you fall shortEach explanation names its module. Reread those modules, then select New set of questions.
What a pass meansA pass shows that you know the material. It does not show that you can do the work. Competence is demonstrated on your unit’s own equipment and signed off by a preceptor.

End-of-course examination

Question 1Who decides that a repaired machine is technically fit, and who accepts it for patient use?
Question 2How should any machine that has been used on patients be regarded before service?
Question 3What is the purpose of lockout/tagout?
Question 4A machine passes its self-test after an unexplained conductivity alarm. What does this prove?
Question 5Why must repairs follow the manufacturer’s service manual?
Question 6What is the main purpose of an out-of-service tag?
Question 7Which practice protects circuit boards from static damage?
Question 8A machine assigned to the hepatitis B isolation area is repaired in the workshop. Where does it go afterward?
Question 9Before using a service procedure, which three things should match the machine in front of you?
Question 10You find dried blood around an internal pressure port. What does this tell you?
Question 11In the water picture of electricity, what is voltage most like?
Question 12A heater element of 23 ohms is connected to 230 volts. About how much current flows?
Question 13A fuse blows a second time after replacement. What is correct?
Question 14What does the protective earth connection do?
Question 15Which measurement must only be made with the machine unplugged?
Question 16A sensor reading is jumping and a connector feels warm. What kind of fault is likely?
Question 17Why do machines have two sensors for safety-critical quantities?
Question 18How should a circuit board be handled?
Question 19Why is water degassed before concentrates are added?
Question 20Why must dialysate never be allowed to overheat?
Question 21What does the heat exchanger do?
Question 22Six machines alarm for low water at shift start. Where is the cause most likely?
Question 23The display reads lower than a reference thermometer. Why is this the more worrying direction?
Question 24A heater has power but water is not flowing past it. What happens?
Question 25One machine warms slowly while its neighbors are normal. What do you check before replacing parts?
Question 26Bubbles in the dialysate lines and unstable conductivity suggest a problem with which stage?
Question 27What does dialysate conductivity measure?
Question 28What is bypass?
Question 29Why can a wrong concentrate sometimes produce a normal conductivity reading?
Question 30Against what is a machine’s conductivity sensor verified?
Question 31By roughly how much does conductivity change per degree Celsius?
Question 32Your reference meter and the machine disagree by several percent, and both pass their own checks. What should you suspect first?
Question 33A nurse asks you to adjust conductivity so an alarm stops. What is correct?
Question 34A machine borrowed from another center will not stabilize conductivity. What do you check?
Question 35In a balancing-chamber machine, where does the fluid taken by the ultrafiltration pump come from?
Question 36One machine consistently leaves patients heavier than expected, with no alarms. What is the most likely area of fault?
Question 37A machine is set to remove 2,000 mL and you collect 2,100 mL in the test. What is the error?
Question 38Why is the tightness test done before the ultrafiltration accuracy check?
Question 39Transmembrane pressure rises steadily through a treatment. What is a likely cause?
Question 40On a volumetric machine, what does the operator set?
Question 41Which is an independent daily check on every machine’s fluid removal?
Question 42Wet, worn seals on the dialyzer connectors can cause which problem?
Question 43How does the machine arrive at the blood flow shown on the screen?
Question 44Why is pre-pump arterial pressure normally negative?
Question 45What is the purpose of a transducer protector?
Question 46Can a venous pressure alarm be relied on to detect a dislodged needle?
Question 47The display shows 350 mL/min. A delivery test collects 1,575 mL in 5 minutes. What is the true flow?
Question 48The unit changes to a different brand of heparin syringe. What must be checked on every machine?
Question 49A pressure display does not read zero with the port open to air. What is needed?
Question 50Why must the hand crank be present on every machine?
Question 51What must happen when the air detector senses air above its limit?
Question 52What does the blood leak detector examine?
Question 53A protective system cannot be made to pass its test before the next shift. What is correct?
Question 54Which is a likely cause of an air detector failing to alarm?
Question 55What does single-fault safety mean?
Question 56What can the machine’s start-up self-test not prove?
Question 57Operators report frequent false blood leak alarms on one machine. How should this be treated?
Question 58You find a jumper wire across a door switch. What do you do?
Question 59What is preventive maintenance?
Question 60A center has ten machines with a six-month maintenance interval. About how many visits are needed per year?
Question 61A center has fourteen machines on a six-month interval. How many visits are due each year?
Question 62Why should patient scales be in the equipment inventory?
Question 63What is the first step when a manufacturer’s safety notice arrives?
Question 64Before starting a maintenance visit, whom should you ask about the machine?
Question 65Most of your downtime is machines waiting for parts. What should change?
Question 66After a software update, what must be recorded?
Question 67What does calibration mean?
Question 68Why record the as-found value before adjusting?
Question 69A reference meter is past its calibration due date. What is correct?
Question 70What does traceable mean for a reference instrument?
Question 71A reference meter is discovered to have been reading wrong. What must be reviewed?
Question 72Which item belongs in every service record?
Question 73The tolerance is ±0.5 °C. The machine shows 37.0 and a reference thermometer reads 37.4. What is correct?
Question 74Why should you never dip a probe directly into the stock bottle of standard solution?
Question 75What is scale inside a dialysis machine mostly made of?
Question 76Which agent removes scale?
Question 77Why must bleach and acid programs never be run back to back without rinsing?
Question 78What does a residual test show?
Question 79Residual test strips have run out. What is correct?
Question 80The machine displays “disinfection complete.” What still has to be shown before use after a chemical program?
Question 81Why must the drain hose end above the drain with a visible gap?
Question 82A dialysis fluid filter fails its integrity test. What is correct?
Question 83What is the purpose of the protective earth connection?
Question 84When is an electrical safety test required apart from the scheduled interval?
Question 85Why are dialysis patients especially vulnerable to small electrical currents?
Question 86A nurse feels a tingle from a machine’s metal case. What is the correct first action?
Question 87Why is the power cord flexed during the protective earth test?
Question 88Why are extension leads not used for dialysis machines?
Question 89On mains failure, what does a machine’s internal battery commonly keep running?
Question 90A machine passes its electrical safety test but its wall outlet has no earth. Is the patient protected?
Question 91Three machines fed by the same concentrate line alarm for low conductivity within minutes. What is the most likely cause?
Question 92What is the first step in fault-finding?
Question 93Why check simple causes first?
Question 94A part was replaced and the alarm stopped, but the reason the part failed is unknown. What is true?
Question 95The fluid path was opened during a repair. What is required before release?
Question 96A required post-repair test cannot be completed before the next shift. What is correct?
Question 97Who accepts a repaired machine for clinical use?
Question 98Which indicator should always be zero?
Question 99A new machine arrives. What must happen before its first patient?
Question 100After fixing a worn seal that caused an intermittent alarm, what is the most valuable next step?
Dr. William Gregory M. Rivero, MD

William Gregory Rivero, MD, FPCP, DPSN

Internal Medicine · Nephrology · Nutrition · Philippines · PRC 0105184

Educational study material for biomedical technicians. Does not replace the manufacturer’s service manual and training, approved facility procedures, applicable electrical and medical device regulations, or supervised practice.

QR code — scan to save Dr. Rivero's contact info

Scan and save