How this examination works

This examination covers the whole Water Treatment System Technician series. Each sitting draws 30 questions at random from a bank of 104, in random order, with the answer choices shuffled. Choose the single best answer for each question, then select Check answers.

When to take itAfter you have finished every module and reviewed the questions you missed.
How to take itIn one sitting, without notes. Allow about one minute per question.
Proposed pass mark24 of 30 best answers (80 percent). Your trainer may set a different mark.
If you fall shortEach explanation names its module. Reread those modules, then select New set of questions.
What a pass meansA pass shows that you know the material. It does not show that you can do the work. Competence is demonstrated on your unit’s own equipment and signed off by a preceptor.

End-of-course examination

Question 1Why must dialysis water be cleaner than drinking water?
Question 2Which contaminant destroys red blood cells and is removed mainly by carbon tanks?
Question 3What is endotoxin?
Question 4In the international standard, what is the maximum total chlorine in dialysis water?
Question 5Which fluid has the strictest limits for bacteria and endotoxin?
Question 6What is an action level?
Question 7The utility announces a higher disinfectant dose. The reverse osmosis display is normal. What should you do first?
Question 8Who carries overall responsibility for dialysis water quality in a facility?
Question 9A test kit reports hardness as 2 grains per gallon. About how many mg/L as calcium carbonate is that?
Question 10Several patients’ hemoglobin levels fall over two months with no other explanation. Which water problem should a technician think of first?
Question 11A unit switches from city water to a deep well. What is true of the well water?
Question 12Which valve must be closed and locked or tagged during treatment?
Question 13Iron in the feed water mainly threatens which components?
Question 14Why does adding stations threaten the carbon tanks even if the reverse osmosis unit keeps up?
Question 15What is validation?
Question 16A tanker delivers water during a shortage. How is it handled?
Question 17After a service visit, what is checked before release?
Question 18On a feed water report, which line most directly tells you how hard the softener must work?
Question 19A filter reads 58 psi before and 46 psi after. What is the pressure drop?
Question 20What does a softener remove?
Question 21Why are softeners set to regenerate outside treatment hours?
Question 22After a power interruption, which softener check comes first?
Question 23During a backwash, in which direction does water flow through the bed?
Question 24Sand appears in the drain during backwash. What does this suggest?
Question 25A clock-based softener runs out early during an unusually busy week. Why?
Question 26Pressure is normal at the feed gauge and after the sediment filter, but low after the softener. Where is the problem?
Question 27A carbon bed of 240 liters receives 40 liters per minute. What is the empty-bed contact time?
Question 28Chlorine is detected after the first carbon tank but not after the second. What does this mean?
Question 29Does backwashing restore exhausted carbon?
Question 30A new 5-micrometer cartridge clogs in three days. What is the best interpretation?
Question 31Which test detects chloramine?
Question 32Where is the first chlorine sample of the day taken?
Question 33Chlorine is above the limit after the second carbon tank. What happens next?
Question 34Why must the color be read at exactly the stated time?
Question 35A unit uses a free chlorine test. The utility switches to chloramine. What will the test show?
Question 36Why test the feed water with the same kit once a week?
Question 37After carbon replacement, what must be done before release?
Question 38Which carbon is not used for dialysis water treatment?
Question 39What passes through a reverse osmosis membrane most easily?
Question 40Feed conductivity is 500 and product conductivity is 25. What is the percent rejection?
Question 41Feed flow is 20 liters per minute and product flow is 12. What is the percent recovery?
Question 42Rejection has fallen steadily for three weeks but no alarm has sounded. What should you do?
Question 43Which of these does conductivity NOT detect?
Question 44Product flow drops on an unusually cold morning with no other change. What is the most likely reason?
Question 45Product flow is rising and rejection is falling. What is the most likely cause?
Question 46The low feed pressure alarm stops the pump. What is checked first?
Question 47Why does the loop return water to its starting point?
Question 48What is a dead leg?
Question 49Cultures are under 5 CFU/mL at the loop start and 38 CFU/mL at the loop return. What does this suggest?
Question 50What is the main weakness of a tank-fed system?
Question 51Why is an ultrafilter placed after an ultraviolet lamp?
Question 52An ultraviolet lamp is glowing. Does that prove it is working?
Question 53Which material must not contact product water?
Question 54Loop cultures are clean, but dialysis fluid from two machines is above the action level. Where do you look?
Question 55Why are acid and bicarbonate supplied as two separate concentrates?
Question 56Two acid concentrates differ only in potassium. Will the machine’s conductivity alarm tell them apart?
Question 57Which water is used to mix bicarbonate concentrate?
Question 58Why should bicarbonate not be mixed vigorously for a long time?
Question 59A bicarbonate container is half full of yesterday’s batch. What is correct?
Question 60Low conductivity alarms occur on six machines at once shortly after a new bicarbonate batch goes on line. What is the likely cause?
Question 61By convention, which color marks acid concentrate connectors?
Question 62A mixed batch fails verification. What do you do?
Question 63Which log entry is acceptable?
Question 64You forgot the midday chlorine test. What do you write?
Question 65Pressure drop across the sediment filter has risen a little every week for a month. No limit has been reached. What should you do?
Question 66Product conductivity is excellent today. What does this tell you about chlorine?
Question 67What is a baseline?
Question 68A log shows the same pressure reading to the decimal for three weeks. What does this most likely indicate?
Question 69Who should carry out the weekly log review?
Question 70What is the last step of the start-of-day round?
Question 71In the international standard, what is the bacteria limit for dialysis water?
Question 72A culture result lies between the action level and the limit. What does this mean?
Question 73When are routine culture samples best taken?
Question 74Why is the sample port flushed before collecting?
Question 75How often is chemical analysis of product water done, at a minimum, in most monitoring plans?
Question 76A laboratory cultures dialysis water at body temperature for 48 hours. What is the likely effect?
Question 77Endotoxin is high but the culture is low. How should this be treated?
Question 78How should culture samples be stored before transport?
Question 79What is biofilm?
Question 80After a chemical disinfection, what must be shown before any patient is connected?
Question 81Why must bleach never be mixed with acid products?
Question 82Several patients on one shift develop chills at about the same time. What is the technician’s first step?
Question 83A procedure calls for 100 liters at 2 percent. The stock is 10 percent. How much stock is needed?
Question 84Why are two different test strips used during chemical disinfection?
Question 85Counts return to their old level two weeks after disinfection. What does this suggest?
Question 86Why might the reverse osmosis membrane and the loop have different disinfection procedures?
Question 87What triggers carbon replacement before its scheduled date?
Question 88After carbon is replaced, which check is essential before release?
Question 89A new reverse osmosis membrane has been fitted. What should be recorded?
Question 90A section of loop pipe was opened for repair. What is required?
Question 91An engineer leaves a report saying only “Serviced. OK.” What is correct?
Question 92Why write the installation date on each replaceable part?
Question 93A pressure gauge has read exactly the same value for a month. What should you suspect?
Question 94What is the first step before any maintenance that takes a stage out of service?
Question 95What are the first three moves for any out-of-range water result?
Question 96The first chlorine test is above the limit; a repeat is below it. What is correct?
Question 97Who decides what happens to patients already on dialysis when the water is in doubt?
Question 98Several patients have fever and chills and contamination is suspected. Why sample before disinfecting?
Question 99Power returns after a long outage. What should be checked before treatment resumes?
Question 100Delivered tanker water arrives during a supply cut. How should it be regarded?
Question 101Which is a root cause rather than a description?
Question 102Before handling a disinfectant for the first time, what do you read?
Question 103In an urgent water report, which fact tells the nurse how many patients are at risk right now?
Question 104You cannot reach the charge nurse within a minute during a breakthrough. What do you do?
Glossary & abbreviationsTalahulugan at mga daglatTalaan sa mga pulong ug daglatTalatinigan ampo reng daglat terms used on this page

Abbreviations

CFU
Colony-forming unit — The count of viable bacteria in a water sample.
EU
Endotoxin unit — The measure of bacterial endotoxin in a water sample.