Renal Technician Program · For trainers

Trainer and Preceptor Resource

Program structure, completion criteria, and printable skills checklists for the Water Treatment System Technician series.

PublishedNailathalaGipatikPepalwal: ReferencesMga SanggunianMga TinubdanReng Reperensya: 1 Audience: Head nurses, chief technicians, educators, and preceptors Read timeOras ng pagbasaOras sa pagbasaOras ning pamamasa:
Renal Care Academy›Water Treatment System Technician›Trainer and preceptor resource

Using the series to train water room staff

Use the twelve modules as guided study alongside hands-on training on your own system. A practical sequence is one module a week, each followed by supervised practice of its checklist in the water room.

Figure 1 · Suggested sequence

  1. Walk the systemTrace every pipe from feed water to drain with the drawing in hand.
  2. Study the moduleRead, work the case, and take the self-assessment.
  3. DemonstrateThe preceptor performs the skill and explains each step.
  4. PracticeThe learner performs it under observation, several times.
  5. Sign offRecord competence on the unit’s own form.

The medical director should approve the limits, action levels, and procedures the learner is taught.1

Proposed completion criteria

These are proposals for the facility to adapt.

Written examination. The end-of-course examination draws 30 questions at random from the question banks of all modules. A proposed pass mark is 80 percent, with missed questions reviewed against their modules before a second sitting. For a supervised sitting, the learner takes it on a unit device with the preceptor present and the preceptor records the score.

Skills checklists for every module

Print this page for a full set. Each checklist starts on a new sheet. Steps marked Critical must all be satisfactory before sign-off; a missed critical step is repeated with the preceptor. Replace any step that does not match your equipment or approved procedure.

Module 1: Why Dialysis Water Is Different

Tracing the system and explaining the risks. Materials: the system drawing, the unit’s list of limits, and the water room itself.

Observable stepSatisfactoryNeeds practiceNot observed
Traces the water path from the feed line to the loop return on the drawing and in the room.
Names what each stage removes.
CriticalStates the unit’s limit and action level for total chlorine, bacteria, and endotoxin.
CriticalExplains why a normal reverse osmosis reading does not prove the absence of chlorine.
CriticalIdentifies who must be told when water quality is in doubt, and how to reach them.
Locates the written procedures and the log for the water system.

Learner ____________________   Preceptor ____________________   Date __________

Module 2: Source Water and System Design

Reading the system drawing and the feed water report. Materials: the system drawing, valve tags, the most recent feed water analysis, and the design-stage analysis.

Observable stepSatisfactoryNeeds practiceNot observed
CriticalNames the unit’s water source or sources and how the unit is told of a change.
Traces the drawing from feed to drain and matches each numbered valve to its tag.
CriticalStates the normal position of every bypass valve and shows how each is locked or tagged.
Reads five lines of the feed water report and says which component each affects.
Compares the current report with the design-stage report and points out any change.
Explains what would raise the unit’s peak demand.
CriticalStates who approves use of the system after a major change.

Learner ____________________   Preceptor ____________________   Date __________

Module 3: Sediment Filtration and Softening

Filter and softener round with a hardness test. Materials: the log, a hardness test kit, the softener manual, and the system drawing.

Observable stepSatisfactoryNeeds practiceNot observed
Reads both gauges on each filter, calculates the pressure drop, and compares it with the clean value.
States the pressure drop at which the unit backwashes or changes each filter.
CriticalChecks the backwash and regeneration timers against the real time.
Checks the salt level and tests for a salt bridge.
CriticalPerforms a hardness test at the correct port and records the value with its unit.
CriticalStates the action for a hardness result above the unit’s limit.
Finds the point of pressure loss in a simulated low-pressure problem by reading gauges in order.

Learner ____________________   Preceptor ____________________   Date __________

Module 4: Carbon Tanks and Chlorine Control

Total chlorine test and daily log. Materials: the unit’s total chlorine test kit, a timer, the sample ports, and the log.

Observable stepSatisfactoryNeeds practiceNot observed
Confirms the system has been running for the stated time before sampling.
CriticalChecks that the kit is a total chlorine test and is in date.
CriticalSelects the correct sample port and flushes it for the stated time.
CriticalFollows the kit instructions exactly, including the reading time.
Records the value, unit, port, time, and name.
CriticalStates the correct action for a result above the limit after the worker tank and after the polisher.
Completes the remaining daily readings with numbers and units and signs the release.
Points out one trend in the past month’s log and says whom to tell.

Learner ____________________   Preceptor ____________________   Date __________

Module 5: Reverse Osmosis

Reverse osmosis readings, calculations, and alarm response. Materials: the unit’s display and gauges, the log with at least one month of readings, a calculator, and the alarm list from the manual.

Observable stepSatisfactoryNeeds practiceNot observed
Confirms pretreatment status and valve positions before start-up.
Waits for steady running before recording.
Records all pressures, flows, conductivities, and temperature with units.
CriticalCalculates percent rejection and percent recovery correctly.
Compares with last month and describes any pattern and its likely cause.
CriticalStates the action for each alarm on the unit’s alarm list.
CriticalReports a simulated high product conductivity alarm to the charge nurse with stations affected.
CriticalExplains why conductivity does not replace chlorine testing or cultures.

Learner ____________________   Preceptor ____________________   Date __________

Module 6: The Distribution Loop, Storage, and Final Filters

Loop walk-down and dead-leg hunt. Materials: the loop drawing, a flashlight, the log, and the lamp and filter records.

Observable stepSatisfactoryNeeds practiceNot observed
States whether the system is direct feed or tank-fed and traces the loop from supply to return.
Records loop supply and return pressures and compares with previous readings.
CriticalConfirms the loop runs continuously, including overnight.
CriticalIdentifies every unused outlet, capped branch, and spare hose coil and reports them.
Checks ultraviolet lamp hours or intensity and the date of the last sleeve cleaning.
Reads the pressure drop across the ultrafilter and its replacement date.
Inspects the storage tank lid and vent filter, if a tank is fitted.
CriticalExplains how machine hoses are disinfected and when they are replaced in this unit.

Learner ____________________   Preceptor ____________________   Date __________

Module 7: Concentrates and Central Delivery

Mixing, labeling, and verifying a bicarbonate batch. Materials: bicarbonate powder, a cleaned mixing container, dialysis water, the unit’s verification instrument, labels, and the batch log.

Observable stepSatisfactoryNeeds practiceNot observed
CriticalConfirms the container has been cleaned and disinfected by procedure and holds no old solution.
CriticalUses dialysis water and fills to the correct mark.
Checks powder type, lot, and expiry and adds the stated quantity.
Mixes gently until dissolved without over-mixing.
CriticalVerifies the batch by the unit’s method and states the acceptable range.
CriticalLabels with contents, time mixed, discard time, lot numbers, and name.
Records the batch in the log.
Reads an acid concentrate label and states formula, proportioning system, lot, and expiry.
CriticalStates the action for a batch that fails verification.

Learner ____________________   Preceptor ____________________   Date __________

Module 8: Daily Monitoring, Logs, and Trends

Start-of-day round and release. Materials: the log sheet with baselines and action points, test kits, and the system itself.

Observable stepSatisfactoryNeeds practiceNot observed
Allows the system to reach steady running before testing.
CriticalPerforms the total chlorine test correctly at the correct port.
Records pretreatment readings and checks timers and salt.
Records reverse osmosis readings and calculates rejection.
Records loop readings and checks lamp and filter status.
Checks concentrate batches and tank levels.
CriticalCompares each reading with its baseline and action point and reports any drift.
CriticalEnters numbers with units, time, and name, with no blanks.
CriticalStates the release to the charge nurse in words and signs it.

Learner ____________________   Preceptor ____________________   Date __________

Module 9: Chemical Analysis and Microbiological Sampling

Aseptic sampling and a documented disinfection. Materials: laboratory sample containers, gloves, the sampling plan, the disinfection procedure, the safety data sheet, and residual test strips.

Observable stepSatisfactoryNeeds practiceNot observed
Labels containers before sampling with point, date, time, and name.
Performs hand hygiene and wears clean gloves.
CriticalFlushes the sample port for the stated time.
CriticalCollects the sample without touching the inside of the cap or container.
Stores and sends the sample as the laboratory requires.
CriticalConfirms no patient is on dialysis and posts warning signs before a chemical disinfection.
CriticalWears the protective equipment listed on the safety data sheet.
Verifies disinfectant at the farthest point and observes the full dwell time.
CriticalRinses and obtains a negative residual test at every outlet before release.
Records concentrations, times, results, and names.

Learner ____________________   Preceptor ____________________   Date __________

Module 10: Disinfection and Biofilm Control

A documented loop disinfection. Materials: the disinfection procedure, the approved disinfectant and its safety data sheet, protective equipment, concentration and residual test strips, warning signs, and the disinfection record.

Observable stepSatisfactoryNeeds practiceNot observed
CriticalConfirms no patient is on dialysis, tells the charge nurse, and posts warning signs.
CriticalReads the safety data sheet and wears the stated protective equipment.
CriticalChecks stock strength and expiry and calculates the dilution correctly.
Doses and circulates by procedure.
CriticalProves working concentration at the farthest point before starting the dwell time.
Observes the full dwell time.
CriticalRinses and obtains a negative residual test at every outlet, including unused ones.
Records concentrations, times, results, and names, and releases the system in writing.
CriticalStates the first aid for skin and eye contact with the disinfectant in use.

Learner ____________________   Preceptor ____________________   Date __________

Module 11: Maintenance, Component Replacement, and Validation

Cartridge change with post-change checks. Materials: a replacement cartridge of the correct type, the housing tool, the drawing and valve list, the log, and a service report form.

Observable stepSatisfactoryNeeds practiceNot observed
CriticalAgrees the timing with the charge nurse and confirms no patient is on dialysis.
Records valve positions and pressure readings before starting.
CriticalIsolates and depressurizes the housing safely.
Fits the correct cartridge and seals the housing without contaminating it.
Flushes to drain and checks for leaks.
CriticalReturns every valve to its normal position and confirms against the valve list.
Records the new clean pressure drop and writes the installation date on the housing.
CriticalStates the post-change checks for carbon, membrane, and pipe work.
CriticalCompletes the record and releases the system in writing.

Learner ____________________   Preceptor ____________________   Date __________

Module 12: Failures, Emergencies, and Capstone

Out-of-range drill. Materials: a simulated log with a chlorine result above the limit, hold tags, the unit’s contingency plan, and an incident form.

Observable stepSatisfactoryNeeds practiceNot observed
CriticalRecognizes the out-of-range result without prompting.
CriticalPlaces a hold and prevents new treatment starts.
CriticalReports to the charge nurse within two minutes with the result, ports, time, and whether patients are connected.
CriticalDoes not replace the first result with a better repeat result.
Lists possible causes without claiming one as fact.
States the tests required before release and who may release.
Completes the incident record with facts, times, and names.
Locates the contingency plan, the reserve volume figure, and the tanker supplier’s contact.

Learner ____________________   Preceptor ____________________   Date __________

ReferencesMga SanggunianMga TinubdanReng Reperensya 1 source
  1. International Organization for Standardization (ISO). (2024). Preparation and quality management of fluids for haemodialysis and related therapies. Part 1: General requirements (ISO 23500-1:2024).
Dr. William Gregory M. Rivero, MD

William Gregory Rivero, MD, FPCP, DPSN

Internal Medicine · Nephrology · Nutrition · Philippines · PRC 0105184

Educational study material for dialysis water treatment staff. Does not replace the medical director’s direction, approved unit procedures, manufacturer instructions, the standard edition your facility follows, DOH licensing requirements, or supervised training.

QR code — scan to save Dr. Rivero's contact info

Scan and save