Renal Care Physicians Track · Module 8 of 20

Dialysis catheters and central veins

Give every catheter an indication, a site that protects the future, and an exit date.

PublishedNailathalaGipatikPepalwal: ReferencesMga SanggunianMga TinubdanReng Reperensya: 2 Audience: Vascular and cardiovascular surgeons with a renal access practice · surgical fellows · general surgeons working under supervision in an institutionally approved access service Read timeOras ng pagbasaOras sa pagbasaOras ning pamamasa:
A procedure room with ultrasound and fluoroscopy, a surgeon checking a guidewire position on the screen while a nurse monitors the patient.
Renal Care Academy›Renal Care Physicians Track›Vascular Surgeon›Module 8 of 20 Training track for surgeons who create and maintain dialysis access
🩺

Training track for surgeons who create and maintain dialysis access

This module is study material for surgeons and supervised surgical trainees in adult dialysis access. It explains the reasoning behind access decisions; it is not an operative manual or a protocol. Device instructions, drug doses and local escalation contacts belong in your institution’s approved protocols. Benefit rules change: confirm them on the date of service. Every case is fictional. Clinical review of this track is pending.

After this module you should be able to

Pre-testBefore you read, answer the 5 self-assessment questions and note your score. After the module, select New set of questions and compare. The difference is what you learned; the questions you still miss are what to reread.

The big picture, in plain words

In plain wordsA dialysis catheter is a temporary bridge across a river. It gets traffic across today, but every day it stands, it erodes the riverbanks it rests on, and one day those banks may be needed for a permanent crossing.

The picture has a limit. A bridge erodes slowly and visibly. A catheter injures the vein wall where it touches and where flow is turbulent; the healing response narrows the vein, often silently, until a fistula in that arm years later swells the limb. Meanwhile a film of bacteria and fibrin, a biofilm, coats the catheter within days, and antibiotics struggle to reach the bacteria inside it.

Figure 1 · Key terms for this module

Tunneled catheterA cuffed catheter tunneled under the skin to the vein, used for weeks to months.
Non-tunneled catheterAn uncuffed catheter for short-term use, usually days.
Fibrin sheathA sleeve of fibrin and cells around a catheter tip that blocks flow.
BiofilmA layer of bacteria in a matrix on the catheter surface, protected from antibiotics.
Exit planThe date and condition under which the catheter will be removed or replaced by an arteriovenous access.

Some patients need a catheter: an urgent start, a failed access, or a short expected course. Your work is to place it where it protects the future, recognize when insertion has gone wrong, and make sure it does not quietly become permanent.

Case: Breathless after the exchange

Mr. Ramon Lacson, 70, had his left subclavian tunneled catheter exchanged over a guidewire this morning by a junior colleague because of poor flow. Two hours later the dialysis nurse calls: the new catheter will not run above 180 mL/min, and Mr. Lacson has become breathless. His oxygen saturation is 89% on room air, down from 97%, and his blood pressure is 96/60 mm Hg. The nurse asks whether to reverse the lines and try again.

There is no chest radiograph after the exchange. His right internal jugular vein was occluded by an old catheter two years ago, which is why the left subclavian was used.

Before reading on, decide:

Keep your answers in mind. The lesson gives you what you need, and the case review near the end shows one sound response.

How catheters injure veins and harbor infection

A catheter moves with every heartbeat and breath. Where its tip or body rubs the vein wall, the endothelium is injured; platelets and fibrin deposit; smooth muscle cells proliferate. The result is fibrin sheath around the catheter and stenosis in the vein wall, worst in the subclavian and brachiocephalic veins, which bend and are compressed between the clavicle and first rib. A catheter on the same side as a future fistula, or alongside a pacemaker lead, adds to this injury.1

Schematic of central veins showing the preferred right internal jugular site, the avoided subclavian route and stenosis sites.
Figure 2. Where a catheter goes, and what it can cost. The UK Kidney Association (UKKA) favors the right internal jugular vein and avoiding the subclavian route, because injured central veins drain future arm access.

Within days, bacteria from the skin or the hub colonize the catheter and form biofilm. Inside it they grow slowly and are shielded from antibiotics and white cells. This is why the same organism often returns after treatment, and why some organisms usually mean removal (Module 15).

ProblemMechanismWhat you may see
Early dysfunctionMalposition, kink, tip against the wallPoor flow from day one, positional flow
Late dysfunctionIntraluminal thrombus, fibrin sheathFalling flow over weeks, high pressures
Central venous stenosisWall injury and healingArm, face or chest swelling, collaterals
InfectionBiofilm on the catheter surfaceFever or rigors at connection, exit-site pus

Where to place it, and what the guidelines say

The UK Kidney Association (UKKA) 2025 guideline gives graded statements on catheter insertion and care. It recommends routinely favoring the right internal jugular vein for tunneled catheters, though imaging, access location and preference may modify the choice (statement 5.1, grade 1C); routinely avoiding the subclavian route where alternative veins are available (5.2, grade 1C); real-time ultrasound for insertion, with fluoroscopy for left-sided or subclavian approaches (5.3, grade 1C); access by trained staff with a strict aseptic approach (5.4, grade 1C); assessment of the exit site and function at each session (5.5, grade 1C); and exit-site disinfection with 2% chlorhexidine (5.6, grade 2C).2

For dysfunction, UKKA recommends locking each lumen with a thrombolytic as initial treatment (6.2, grade 1C), and replacing the catheter, usually by guidewire exchange, when that fails, in a setting where fibrin sheath disruption is available (6.3, grade 1C).2 Repeated manipulation without a diagnosis wastes time and can injure the vein.

Figure 3 · Every catheter needs four answers

  1. Why now?The indication: urgent start, failed access, short course, or patient choice.
  2. Where?The site that protects the planned arteriovenous access.
  3. How was it checked?Imaging used at insertion and position confirmed.
  4. Until when?Review date, removal condition, and who owns it.
RememberA catheter without a removal date tends to become permanent. Write the date when you write the indication.

Insertion complications: when to stop troubleshooting

Most poor flow after insertion is mechanical and fixable. But some complications threaten life: pneumothorax, hemothorax, perforation of a central vein or the right atrium with bleeding into the mediastinum or pericardium, arterial puncture, and air embolism. Their early signs overlap with ordinary problems: poor flow, chest discomfort, breathlessness, low blood pressure. The difference is that the patient is getting worse.

Algorithm for poor catheter flow: stop and escalate if the patient deteriorates; otherwise lock, then exchange.
Figure 4. When to stop troubleshooting. A deteriorating patient after a catheter procedure turns a flow problem into an emergency.

The rule is simple: when a patient deteriorates after a catheter procedure, the problem is the patient, not the flow rate. Stop routine troubleshooting. Do not reverse lines or keep dialyzing through a catheter of uncertain position. Assess airway, breathing and circulation, image the chest, and call the senior and emergency team. Device-specific steps belong to the manufacturer’s instructions and your local protocol; this module rehearses recognition and the decision to stop.

On the floor · Procedure room, fictional

During a right jugular insertion, the guidewire meets resistance at 15 cm. Your trainee wants to push harder. You stop, check the wire under fluoroscopy, see it heading into a small branch, withdraw and redirect under imaging.

What this shows. Resistance is information. Pushing through it turns a nuisance into a perforation.

Illustrative scenario. Names and details are invented.

Stop and callStop using the catheter and call for emergency assessment if a patient becomes breathless, hypotensive, hypoxic, or develops chest pain after insertion or exchange. Confirm catheter position with imaging before any further use.

Back to the case: Breathless after the exchange

The next minute. Tell the nurse to stop dialysis through the new catheter, not to reverse the lines, to give oxygen, to lay him in a position he tolerates, and to call the physician on duty to assess him now. You are on your way, or the emergency team is called.

Your worries. After a left subclavian exchange with poor flow, new hypoxia and low pressure, consider pneumothorax or hemothorax, venous or atrial perforation with mediastinal or pericardial bleeding, malposition, and air embolism. He needs a chest radiograph now, bedside ultrasound for pericardial fluid, monitoring, and senior help. Until position is confirmed, the catheter is not used.

The access plan. His right jugular is already occluded; a left subclavian catheter threatens his left central veins and every future left-arm access. His plan should have named the indication, the expected duration, the planned arteriovenous access and side, and a removal date, and asked whether a fistula or graft could be created to remove the need for a subclavian line.

Skills checklist: Catheter indication, safety and exit plan

Simulation or supervised procedure list. Your preceptor rates each step as satisfactory, needs practice, or not observed. Steps marked Critical must all be satisfactory before sign-off. This checklist supports supervised learning; your unit’s own procedure and competency form are the authority. A printable version of every checklist is on the trainer page.

Placement activity. Simulation or procedure room

Check your understanding

Each visit draws 5 questions at random from this module’s 5-question bank. Choose the single best answer for each, then select Check answers; an explanation appears under the best answer. Select New set of questions for a different mix. A good target is 4 of 5 on two different sets. Nothing you select is sent anywhere; scoring happens in your browser.

Question 1 of 5New breathlessness and hypotension follow poor function of a recently exchanged catheter. What is the best response?
Question 2 of 5What should accompany every catheter indication?
Question 3 of 5UKKA 2025 recommends which vein as the routine first choice for a tunneled catheter?
Question 4 of 5What does UKKA recommend as initial treatment for catheter dysfunction?
Question 5 of 5Why do subclavian catheters particularly threaten future arm access?

Read next on this site

Glossary & abbreviationsTalahulugan at mga daglatTalaan sa mga pulong ug daglatTalatinigan ampo reng daglat terms used on this page

Abbreviations

UKKA
UK Kidney Association.

Terms in plain words

Guidewire exchange
Replacing a catheter over a wire through the same tract.
Pneumothorax
Air in the chest outside the lung, which can collapse it.
ReferencesMga SanggunianMga TinubdanReng Reperensya 2 sources
  1. Saad, T. F., & Weiner, H. L. (2017). Venous hemodialysis catheters and cardiac implantable electronic devices: Avoiding a high-risk combination. Seminars in Dialysis, 30(3), 187–192. https://doi.org/10.1111/sdi.12581
  2. Aitken, E., Anijeet, H., Ashby, D., Barrow, W., Calder, F., Dowds, B., Fielding, C., Gilbert, J., Jones, R., Karunanithy, N., Khawaja, Z., Roberts, E., Robson, M., Shroff, R., Stacey, H., Thomson, P., & Waters, D. (2025). UK Kidney Association clinical practice guideline on vascular access for haemodialysis. BMC Nephrology, 26(1), 461. https://doi.org/10.1186/s12882-025-04374-y
Dr. William Gregory M. Rivero, MD

William Gregory Rivero, MD, FPCP, DPSN

Internal Medicine · Nephrology · Nutrition · Philippines · PRC 0105184

Educational material for surgeons. Completing it is an Academy learning record only. It does not confer CPD units, board certification or eligibility, hospital privileges, or PhilHealth accreditation, and it does not teach operative technique. It does not replace current guidelines, regulations, your institution’s protocols, or clinical judgment. Clinical review of this track is pending.

QR code — scan to save Dr. Rivero's contact info

Scan and save