Dialysis · Vascular Access · Quality Tool

Catheter Exposure & Access Journey Tracker

Count catheter days honestly. This tracker merges overlapping catheter intervals (start-inclusive, end-exclusive), separates catheters that were present from those actually used, and shows days from access creation to sustained two-needle use, with the reason and owner for the path off the catheter.

Published: References: 3 Read time:

← All calculators & tools  ·  Access lifeline guide →

Last ReviewedHuling Na-reviewKatapusang Na-reviewKarinan Na-review:
Instructions
  1. Set the observation window. Dates are start-inclusive and end-exclusive: a window from January 1 to January 11 covers 10 days.
  2. Add each catheter interval (insertion and removal). Overlapping catheters, such as an exchange, are merged so a day is never counted twice. If the removal date is blank, choose whether the catheter is still in place or the date is unknown.
  3. Mark whether each catheter was used for dialysis or only present while an arteriovenous access was in use.
  4. Optionally add the access creation date, the date of sustained two-needle use, why a catheter remains, and the next step with an owner and due date. Print the summary for the access meeting.

All computation runs in your browser; no values are stored or transmitted. Do not enter names or record numbers.

When to Use

Use it to quantify catheter exposure for one patient or to audit a unit, and to make the path off a catheter visible: who owns the next step and when it is due. It describes exposure; it does not estimate infections or deaths prevented.

⚠️

A retained catheter is not automatically a failure

Limited life expectancy, exhausted anatomy, or an informed patient preference can make a catheter the right access. Record the reason and the safety plan rather than counting it against the team.

Catheter Exposure & Access Journey Tracker

First date of reliable use, not first cannulation.

Catheter intervals

—
Catheter-present days
days
—
Of observed days
%
—
Catheter-used days
days
—
Creation to sustained use
days
Timeline: shaded segments are catheter-present days within the window.

    ⚕ Union of half-open date intervals clipped to the window; overlapping catheters are merged. Proportion = catheter-present days ÷ observed patient-days × 100. Descriptive only; no causal estimate.

    Formula & Evidence
    QuantityDefinition
    Catheter-present days|∪ [insertion, removal) ∩ [window start, window end)|
    Catheter exposure (%)Catheter-present days ÷ (window end − window start) × 100
    Catheter-used daysSame union, restricted to catheters marked as used for dialysis
    Creation to sustained useSustained-use date − creation date, in days

    KDOQI 2019 and the UK Kidney Association 2025 guideline both ask teams to minimize avoidable catheter exposure while respecting patient goals; CDC Core Interventions list catheter reduction as one of the bundle elements. Acceptance tests: [Jan 1, Jan 11) = 10 days; overlapping [Jan 1, Jan 11) and [Jan 5, Jan 15) = 14 days, not 20.

    Important: This tool is an educational aid for licensed clinicians and dialysis quality teams. It performs transparent arithmetic on the values you enter; it does not diagnose, predict an individual patient’s risk, or recommend a procedure or drug. All computation runs in your browser; nothing is stored or transmitted. Urgent symptoms (uncontrolled bleeding, a lost thrill, a cold or painful hand, fever with rigors, chest pain or breathlessness) need emergency assessment, not a calculation.
    References 3 sources
    1. Lok, C. E., Huber, T. S., Lee, T., Shenoy, S., Yevzlin, A. S., Abreo, K., Allon, M., Asif, A., Astor, B. C., Glickman, M. H., Graham, J., Moist, L. M., Rajan, D. K., Roberts, C., Vachharajani, T. J., Valentini, R. P., & National Kidney Foundation. (2020). KDOQI clinical practice guideline for vascular access: 2019 update. American Journal of Kidney Diseases, 75(4 Suppl 2), S1–S164. https://doi.org/10.1053/j.ajkd.2019.12.001
    2. Aitken, E., Anijeet, H., Ashby, D., Barrow, W., Calder, F., Dowds, B., Fielding, C., Gilbert, J., Jones, R., Karunanithy, N., Khawaja, Z., Roberts, E., Robson, M., Shroff, R., Stacey, H., Thomson, P., & Waters, D. (2025). UK Kidney Association clinical practice guideline on vascular access for haemodialysis. BMC Nephrology, 26(1), 461. https://doi.org/10.1186/s12882-025-04374-y
    3. Centers for Disease Control and Prevention (CDC). (2024, March 29). Best practices for bloodstream infection prevention in dialysis setting. U.S. Department of Health and Human Services. https://www.cdc.gov/dialysis-safety/hcp/clinical-safety/
    Dr. W Rivero, MD

    W Rivero, MD, FPCP, DPSN

    Specialist in Internal Medicine, Nephrology, and Clinical Nutrition. Practicing integrative and evidence-based nephrology across Quezon City, Pampanga, and Bulacan.

    · Book an Appointment →

    QR code — scan to save Dr. Rivero's contact info

    Scan and save

    All Calculators Related Guides