Dialysis Continuity Scenario Planner

For a single day or shift, compare hemodialysis (HD) sessions due with verified local capacity and confirmed partner-unit transfers, and see which resource limits care. Unknown means not confirmed, never available.

Published: Read time:

← All calculators & tools  ·  Climate extremes & kidney care guide →

Instructions
  1. Pick one time window (a day or a shift) and count whole HD sessions due.
  2. Enter verified slots for staffed chairs, approved water, backup power, and complete kits, each after overhead and reserves.
  3. Enter partner-unit slots accepted for that window and transport-supported transfers.
  4. Read local coverage, transfers, unmet sessions, and the limiting constraint, then repeat for the next window.

All computation runs in your browser; no values are stored or transmitted.

When to Use

Use it in a tabletop exercise before typhoon season and during an event to make the shortfall visible early. Inputs come from operations, engineering, and the partner unit, not from tank volume, generator nameplate, or chair count.

⚠️

When not to rely on it

Not for individual triage, deciding who dialyzes, shortening sessions, or estimating a safe delay. If session needs, timing, or transport differ across patients, cap capacity further or treat the result as indeterminate.

Pearls & Pitfalls
💡

The weakest resource sets capacity

Local slots equal the minimum of chairs, water, power, and kits. Adding chairs does nothing if water supports fewer sessions.

🚫

Pitfalls

(1) Counting the same partner capacity twice across neighboring units. (2) Borrowing spare slots from another day. (3) Entering an unverified number to avoid a blank. (4) Forgetting staff who live in flooded areas.

Dialysis Continuity Scenario Planner

Use one row per day or shift so spare capacity is never borrowed across windows. Leave a field blank if it is not yet verified; enter 0 only if you have confirmed zero.

Whole planned HD sessions
Chairs with a nurse and technician confirmed
After fixed overhead and reserves
Backup power under actual load, after reserves
Excluding reserved and expired stock
Same window; confirmed by the receiving unit
Confirmed rides for the same window

Enter sessions due to begin.

⚕ An escalation prompt for the incident lead and receiving partner. It does not triage individual patients, change sessions, or estimate how long care can be safely delayed.

Evidence & References

Formula

QuantityFormula
Local capacitymin(C, W, E, K)
Covered locallymin(D, local capacity)
Transferredmin(D − local covered, B, T)
UnmetD − local covered − transferred (never negative)
Unknown inputResult marked not confirmed; known bounds shown

References

  1. Sandal S, El Wazze S, Nijjar D, et al. A roadmap for disaster risk reduction and management in kidney care: a scoping review and content analysis. J Am Soc Nephrol. 2025;36(7):1363-1379. doi:10.1681/ASN.0000000635
  2. Blum MF, Feng Y, Anderson GB, et al. Hurricanes and mortality among patients receiving dialysis. J Am Soc Nephrol. 2022;33(9):1757-1766. doi:10.1681/ASN.2021111520
Important: A descriptive planning aid for dialysis incident leads. Synthetic example: 90 due; 80 chairs, 65 water, 70 power, 85 kits; 18 partner slots, 15 rides → 65 local, 15 transferred, 10 unmet; water limits local care and transport limits transfers.