Dialysis · Vascular Access · Cardiorenal

Access Flow and Cardiac Burden

Organize access flow (Qa) and cardiac output (CO) measurements: the Qa/CO percentage, change in Qa from baseline, and warnings when measurements are not comparable. Observational context only; the worksheet assigns no diagnosis.

Published: References: 2 Read time:

← All calculators & tools  ·  Access lifeline guide →

Last ReviewedHuling Na-reviewKatapusang Na-reviewKarinan Na-review:
Instructions
  1. Enter access blood flow (Qa) in mL/min and, if available, cardiac output (CO) in L/min, with the date and method of each.
  2. For a trend, add a baseline Qa with its date, measured by the same method under comparable conditions.
  3. Record symptoms. The worksheet reports ratios and changes; it does not label the result normal or abnormal.

Do not enter the blood pump flow (Qb) set on the machine as Qa: Qb is the extracorporeal circuit flow, Qa is flow through the access itself.

When to Use

When a patient with an arteriovenous access has breathlessness, edema, or rising cardiac filling pressures without another clear cause, or when a high-flow access is being considered for flow reduction. It organizes measurements for the cardiology and access team.

Access Flow and Cardiac Burden Worksheet

Symptoms and context
—
Qa / CO
%
—
Change in Qa
%
—
Days between Qa and CO
days

    ⚕ Qa/CO (%) = (Qa ÷ 1,000) ÷ CO × 100. Change (%) = (current − baseline) ÷ baseline × 100. Descriptive only; no diagnostic category is assigned.

    Formula & Evidence

    Basile and colleagues (96 patients with fistulas, ultrasound dilution) found higher Qa in upper-arm fistulas (mean 1.58 versus 0.95 L/min); Qa of 2.0 L/min or more identified the 10 patients classified with high-output cardiac failure (sensitivity 89%, specificity 100%) and a Qa/CO ratio of 20% or more had sensitivity 100% and specificity 74.7%, in that same small cohort. These are observational signals for assessment, not validated diagnostic thresholds for all dialysis populations. Acceptance cases: Qa 2,000 with CO 6 = 33.3%; Qa 600 to 450 = −25%.

    Important: This tool is an educational aid for licensed clinicians and dialysis quality teams. It performs transparent arithmetic on the values you enter; it does not diagnose, predict an individual patient’s risk, or recommend a procedure or drug. All computation runs in your browser; nothing is stored or transmitted. Urgent symptoms (uncontrolled bleeding, a lost thrill, a cold or painful hand, fever with rigors, chest pain or breathlessness) need emergency assessment, not a calculation.
    References 2 sources
    1. Basile, C., Lomonte, C., Vernaglione, L., Casucci, F., Antonelli, M., & Losurdo, N. (2008). The relationship between the flow of arteriovenous fistula and cardiac output in haemodialysis patients. Nephrology Dialysis Transplantation, 23(1), 282–287. https://doi.org/10.1093/ndt/gfm549
    2. Lok, C. E., Huber, T. S., Lee, T., Shenoy, S., Yevzlin, A. S., Abreo, K., Allon, M., Asif, A., Astor, B. C., Glickman, M. H., Graham, J., Moist, L. M., Rajan, D. K., Roberts, C., Vachharajani, T. J., Valentini, R. P., & National Kidney Foundation. (2020). KDOQI clinical practice guideline for vascular access: 2019 update. American Journal of Kidney Diseases, 75(4 Suppl 2), S1–S164. https://doi.org/10.1053/j.ajkd.2019.12.001
    Dr. W Rivero, MD

    W Rivero, MD, FPCP, DPSN

    Specialist in Internal Medicine, Nephrology, and Clinical Nutrition. Practicing integrative and evidence-based nephrology across Quezon City, Pampanga, and Bulacan.

    · Book an Appointment →

    QR code — scan to save Dr. Rivero's contact info

    Scan and save

    All Calculators Related Guides