After this module you should be able to
- Identify dialysis-specific hazards, including venous needle dislodgement, and choose practical safeguards.
- Coordinate readiness checks and a multidisciplinary drill for the emergencies the unit is likely to face.
- Respond to an event by protecting the patient first, then preserving evidence for a structured review.
- Close corrective actions and check that they actually worked.
Time plan. 2 h study · 2 h workshop · 4 h supervised practice. The supervised hours are arranged by your unit and recorded in its own competency system; this page records self-study only.
Slices of cheese, and where the picture fails
Safety specialists describe defenses as slices of Swiss cheese. Each slice (a checklist, an alarm, a trained nurse, a visible needle site) has holes. Harm happens when the holes line up and a hazard passes straight through. The safety nurse's job is to add slices and shrink holes so they rarely line up.
The picture has a limit. Cheese slices sit still. In a dialysis unit the holes move: an alarm that is reliable for one failure is blind to another, a slice disappears when the power goes out, and the busiest moments (shift change, a crash next door, a typhoon) are exactly when several holes open at once. So the nurse must know which defense covers which failure, and which failures no machine will catch.
Venous needle dislodgement: why the alarm may stay quiet
During hemodialysis the blood pump pushes cleaned blood back to the patient through the venous needle, often at 250 to 400 mL per minute. The machine watches the pressure in the venous line. Most of that pressure comes from the resistance of the narrow needle and tubing, not from the patient's vein. If the venous needle slips out of the arm, the needle and line are still there, still narrow, still resisting flow. The pressure falls only a little, often not enough to cross the alarm limit.1 The pump keeps running and blood pours onto the bed.
Why the arterial needle is different: if the arterial needle comes out, the pump sucks air or the arterial pressure alarm fires quickly. The venous side is the dangerous silent side.
| Safeguard | What it protects against | Its hole |
|---|---|---|
| Access and needles visible at all times (no blanket over the arm) | Unseen bleeding | Patients get cold; staff must re-check and re-teach |
| Secure taping per unit method; line looped and anchored | Needle pulled by line traction | Restless or confused patients |
| Tight venous alarm limits set per protocol after the pressure settles | Larger pressure falls | May still miss dislodgement |
| Wetness or blood-leak sensors where available | Bleeding at the site | Must be placed correctly every time |
| Rounds that look at every site at a set interval | Everything above | Staffing and distraction |
Night shift. Mr. Arnel Bautista, 71, has mild dementia and is dialyzing through a left upper-arm fistula at a blood flow of 350 mL/min. He has pulled at his lines twice tonight. The venous pressure reads 140 mmHg; the alarm limits are set 40 mmHg either side. Nurse Joy, on her round, sees a dark patch spreading on the sheet under his elbow. The venous needle is lying beside the arm, still taped to the line. The venous pressure now reads 115 mmHg. No alarm has sounded.
She stops the blood pump, clamps the venous line and the needle, presses on the site with gauze, and calls the charge nurse and the physician on duty. She checks his blood pressure, pulse and level of alertness, and estimates the blood on the sheet. She has the blood loss assessed by the physician, who decides on blood tests and whether to continue treatment. She writes the times, the pressures before and after, and the taping method, and files an incident report that shift.
At the next safety huddle, Joy brings the pattern, not the person: a restless patient, an access under a sleeve, an alarm that fell only 25 mmHg. The unit agrees on a plan for high-risk patients (visible access, extra anchoring loop, a station closer to the nurses' desk, rounds every 15 minutes) and she adds it to the hazard-round checklist.
What this shows. The pressure fell, but not enough to cross the limit, exactly as the physiology predicts. Eyes on the site caught what the machine did not. The response came first; the system fix followed.

When the venous needle slips out, the line still resists flow, so the pressure alarm may not sound; at 300 mL a minute about 1.5 liters can be lost in five minutes.
Make hazards visible before they harm someone
Do a short hazard round at least monthly, at different times of day, with a fresh eye. Look for the ordinary things that cause the most harm.
On a hazard round, Nurse Ronnie asks three nurses to show him the emergency disconnection instructions for the new machine model. Two cannot find them. The cards are in a binder in the head nurse's office.
He arranges for a laminated card at every station and a five-minute practice on an unconnected machine during each shift handover that week. He records the action, the owner and the date he will check that every station still has its card.
What this shows. A safeguard in the wrong place is a hole in the cheese. The hazard round found it before a power cut did.

A hazard round looks for ordinary safeguards: visible access, secured lines, a checked cart, a disconnection kit at every station.
Prepare for the event the unit may actually face
Philippine units face typhoons and floods every year, earthquakes along active faults, power interruptions, and water supply failures. Disasters harm dialysis patients twice: through the event itself and through missed treatments afterward, when potassium and fluid build up. A review of disasters and kidney care describes the recurring pitfalls: units without written plans, patients without emergency instructions or diet guidance for missed sessions, lost records, staff unable to reach work, and no agreements with backup units.2 In the United States, dialysis facilities must keep an emergency plan, train staff and orient patients under federal emergency preparedness rules; this is a useful comparator, not a Philippine requirement.3
| Event | First priorities | Prepare ahead |
|---|---|---|
| Power interruption | Keep alarms active; uncover every needle site; machines on battery or hand-crank blood return per manufacturer | Generator test log; uninterruptible power for machines where installed; drill blood return without power |
| Water failure | Stop starting new treatments; finish or end current ones per protocol | Agreement with technicians and backup units (Module 12) |
| Earthquake | Protect patients in place; then assess and disconnect if evacuation is ordered | Machines secured; drill "drop, cover, hold" for staff and patients on lines |
| Typhoon and flood | Reschedule early; dialyze before the storm where possible | Patient contact list, diet plan for missed sessions, backup unit list, staff transport |
| Fire | Emergency disconnection; evacuate by plan; account for every patient | Evacuation routes, patient accounting sheet, drills |
Patient accounting. In any evacuation, a named nurse holds the census and checks every patient off at the assembly point. Missing patients are reported at once.
Your role and its limits. The safety nurse plans, checks readiness and runs drills. During a real event the charge nurse and physician direct the response, licensed engineers and technicians handle the building and machines, and advanced cardiovascular life support (ACLS)-trained staff run resuscitation.

Each likely emergency has first priorities at the bedside and preparation that must happen beforehand.
Run drills that change what people do
A drill is a test of the plan, not a performance for an inspector. A drill that goes perfectly has usually tested too little. The aim is to find the gaps (the missing clamp, the phone number nobody updated, the nurse who has never returned blood by hand) while no patient is at risk.
| Drill type | How it runs | What it can show |
|---|---|---|
| Tabletop | Staff talk through a scenario at a table, step by step, with the written plan open | Gaps in the plan, unclear roles, missing contacts |
| Skills station | Each nurse performs emergency disconnection or manual blood return on an unconnected machine | Who cannot yet do it; machine-specific differences |
| Unannounced functional drill | A scenario called mid-shift (for example, "power is out at station row B"), with an observer and a stopwatch, without disconnecting real patients | Time to uncover every access, account for every patient, reach the physician and the technician |
Debrief within the hour. Ask three questions: what was supposed to happen, what actually happened, and what we will change. Record each change with an owner and a check date, and test it at the next drill.
Include the patients. Patients should know what to do in an earthquake while connected, which unit to go to if theirs is closed, and how to follow an emergency diet when a session is missed. Teach it in small parts over several sessions and check with teach-back (Module 5).
Nurse Ronnie runs an unannounced power-failure drill at 10 a.m. with the charge nurse's agreement. The observer times how long it takes until every access site is uncovered and every station has its disconnection card in hand. Most stations take under a minute. Station 14 takes four minutes: the nurse there had been pulled to help with a transfusion, and nobody covered her patients.
The debrief does not blame her. The unit adds a rule: in any alarm event, the charge nurse names who covers each empty station. At the next drill, the slowest station takes 70 seconds.
What this shows. The gap was in coverage, not in skill. Only a timed drill could find it, and only a repeat drill could show that the fix worked.
Respond first, investigate second
- Protect the patientStop the pump, clamp, apply pressure, call for help, start resuscitation if needed.
- Make safeRemove the hazard from use for others (a faulty line set, a mislabeled vial).
- PreserveKeep the device, packaging, lot numbers and machine log; write times.
- ReportThrough the unit's incident system the same shift, in facts, without blame.
- ReviewAsk what made the error possible: workload, design, training, communication.
- Act and checkCorrective action with owner, date and a test of whether it worked.
Human factors. Most errors are made by competent people in systems that make the error easy: look-alike vials, a confusing screen, an interruption at the wrong moment, a missing card. Corrective actions that only say "re-educate staff" or "be more careful" are the weakest kind. Stronger actions change the system: remove the look-alike vial, add a forcing step, move the card to the station.
Case: The blanket and the blackout
Thursday, 2:05 p.m. A storm has been building all afternoon. The lights flicker and go out; machines switch to battery and alarms sound across the unit. The generator has not started.
At station 6, Mrs. Ligaya Ramos, 71, has a forearm fistula and is wrapped in a blanket up to her chin because she was cold. You cannot see her needle sites. A new nurse says, "Silence all the alarms so we can think." Another is searching for the emergency disconnection instructions, which are not at the stations.
Before reading on, decide what you would assess, whom you would contact and what you would say, what you would teach, and what would make you escalate. Then compare with the debrief below.
Assess
Communicate
Teach
Escalate
Mrs. Ramos's venous needle was secure, but her tape was lifting. The generator started after six minutes; blood was returned manually on two machines whose batteries ran low. The review found the instruction cards in an office binder and the generator overdue for testing. Both were fixed and checked again two months later.
Submit: A one-page plan for the next 24 hours: rescheduling, patient contact and missed-session diet reminders, backup units, staff transport, and what the safety nurse reports to the charge nurse.
Check your understanding
Each visit draws 5 questions at random from this module’s 15-question bank, in a shuffled order. Choose the single best answer for each, then select Check answers; a rationale appears under every option. Select New set of questions for a different mix. Nothing you select is sent anywhere; scoring happens in your browser and records self-study only.
What this module builds
| Code | The learner can | Course evidence |
|---|---|---|
| S6 | Recognize a system hazard (transmission, emergency, water or equipment) and stop harm before investigating. | infection prevention and control (IPC) observation set, drill debrief, stop-use and release record |
Performance evidence for this module: One hazard round with actions, one multidisciplinary drill with debrief, and one corrective-action effectiveness check.
- Event or drill type, date, shift, participants
- What was expected to happen (the plan)
- What actually happened, with times
- What helped (keep)
- What got in the way (equipment, communication, training, staffing)
- Patient accounting completed (yes/no, time)
- Corrective actions: action, owner, due date, strength (weak/strong)
- How effectiveness will be checked, and when
- Effectiveness confirmed (date, by whom)
Print it or copy it into your unit’s own form. Use it with fictional data here; real entries belong only in the facility’s approved records.
Portfolio measure. Corrective actions verified effective divided by corrective actions due; balanced by drill safety, staff workload and patient interruption burden.
With your preceptor
Drills are run on unconnected machines or in tabletop form; never practice emergency disconnection on a patient. These are prompts for supervised learning, not a procedure. Use your center’s own protocols, contacts and forms; your preceptor observes and signs off each item on the facility’s competency record.
- Do a hazard round on two shifts and record at least three findings with owners.
- Check every station for the emergency disconnection kit and machine-specific card.
- Run a power-failure drill including manual blood return on an unconnected machine.
- Run a tabletop typhoon exercise with the charge nurse, technician and physician.
- Review two past incident reports and grade each corrective action as weak or strong.
Read next on this site
- Typhoon and Disaster Preparedness for DialysisTyphoon and disaster preparedness for dialysis patients.
- Cardiac Arrest Response in a Dialysis UnitResuscitation in the dialysis unit.
- Managing Complications of HemodialysisComplications during hemodialysis.
- Hemodialysis Nurse Module 9: Responding to complications during a sessionRelated Renal Care Academy module.
Back to the Special Dialysis Nurse Roles home · the Hemodialysis Nurse core course.