Nursing Education · Module 10

PD and Home Dialysis Nursing

Dialysis that the patient performs at home, using the lining of the abdomen as the filter. How exchanges work, how infection enters, what cloudy fluid means, and how a nurse judges that a patient or caregiver is ready.

PublishedNailathalaGipatikPepalwal: ReferencesMga SanggunianMga TinubdanReng Reperensya: 13 Audience: Registered nurses entering nephrology or hemodialysis practice · nurse educators and preceptors Read timeOras ng pagbasaOras sa pagbasaOras ning pamamasa:
Nurse teaches a patient to prepare a clean space for home peritoneal dialysis.
Renal Care Academy› Nephrology Nursing & Hemodialysis›Module 10 Nephrology Nursing path: emphasized Hemodialysis Nursing path: foundation
🩺

Self-study for registered nurses

This module is self-study for registered nurses. It explains the reasoning behind safe practice; it does not replace the physician’s orders, your unit’s approved procedures, or the manufacturer’s instructions for the equipment you use. Every case is fictional. A quiz score records self-assessment only; practice competencies are observed and signed off by a clinical preceptor or training provider.

After this module you should be able to

The filter is already inside

Picture a sponge soaked in a basin of clean water. Wastes seep out of the sponge into the water. Pour the water away, refill the basin, and the sponge gives up a little more. In peritoneal dialysis (PD) the sponge is the blood in the small vessels of the peritoneum, the thin membrane that lines the abdomen. The basin is the abdomen itself, filled through a soft catheter with dialysis solution.

The picture has a limit. A sponge only gives things up. The peritoneum is a living barrier that moves water and wastes in both directions, and how much it moves depends on the solution, the time, and the patient’s own membrane. The next sections give the real physiology.

PD needs no needles and, in its manual form, no machine. It happens at home, gently and every day. The price of that freedom is that the patient or a family member becomes the operator, several times a day. Most peritonitis traces back to one moment when a sterile connection was touched. Your work is to teach the exchange, to confirm by observation that the operator can do it safely, and to act the same day when the drained fluid turns cloudy.

In PD, the nurse’s main tool is teaching, and the main test of teaching is what the operator does with their own hands.

Exchanges, transport, and types

One exchange has three phases. During drain, the used fluid, called effluent, flows out by gravity. During fill, fresh solution flows in, usually about 2 liters in an adult. During dwell, the solution stays in the abdomen and does its work.

Two processes act during the dwell. Small solutes such as urea and potassium diffuse from the blood in the peritoneal capillaries into the fluid, down their concentration difference. Water follows by osmosis, because the solution contains glucose, or another osmotic agent, at a higher concentration than blood. A stronger glucose solution pulls more water. Over a long dwell, glucose is absorbed and the pull fades. That is why dwell time and solution strength are prescribed together.

Manual exchangesAutomated exchanges
NameContinuous ambulatory peritoneal dialysis (CAPD)Automated peritoneal dialysis (APD)
HowThe patient connects a twin-bag set and exchanges by gravity, typically three to five times a dayA cycler machine performs several exchanges overnight. There may be a daytime dwell
NeedsA clean surface, a hook or stand, hand hygiene, and about 30 minutes per exchangeA cycler, reliable electricity, and space at the bedside
Connections per daySeveralUsually one connection and one disconnection

How infection enters. Organisms reach the peritoneum by three main routes. The first is through the inside of the tubing, when a connection is touched. The second is along the outside of the catheter, from an infected exit site or tunnel. The third, less often, is from the bowel. Technique controls the first two. The catheter leaves the skin at the exit site. A healthy exit site is dry, with no redness, swelling, or discharge.

Every connection is a door into the abdomen. Ask, for each step you teach, which door it keeps shut.

The membrane in depth: why the same bag behaves differently in different people

The capillary wall is the real filter. We call the peritoneum the membrane. The barrier that decides what crosses, though, is the wall of the small blood vessels running through it. Picture that wall as a sieve with two kinds of opening. Gaps between the lining cells let water and small solutes pass together: urea, creatinine, potassium, and glucose. Much smaller channels through the cells let only water pass.

The picture has a limit. A sieve has fixed holes. The capillary wall is alive, and the number of vessels in contact with the fluid differs from person to person and changes over the years. Two consequences follow. Small solutes move by diffusion, quickly at first and then more slowly as the fluid comes to resemble blood. Water moves only while the solution is more concentrated than blood. Glucose is itself a small solute, so it leaks back into the blood through the same gaps. The pull on water is strongest in the first hour or two and then fades. If the dwell runs long after the glucose gradient is gone, fluid is reabsorbed and the patient drains less than was filled.

That is why glucose strength and dwell length are prescribed as a pair. Glucose solutions come in three strengths, commonly labeled 1.5%, 2.5%, and 4.25% dextrose. A stronger bag removes more water. It also delivers more glucose to the patient and, over years, to the membrane. The prescriber therefore uses the weakest strength that keeps the patient at target weight.

Transport type. The peritoneal equilibration test measures how fast this particular membrane works. A standard bag dwells for 4 hours. Samples of fluid and blood show how fast creatinine has entered the fluid and how fast glucose has left it. The result places the patient on a scale from fast to slow transport and guides the prescription.1

Fast transporterSlow transporter
Small solutesEquilibrate quicklyEquilibrate slowly
Glucose gradientLost early, so water removal is poor on long dwellsKept longer, so water removal is sustained
Typical problemFluid overload, low drain volumes after long dwellsSolute removal that is too low if dwells are short
Prescription that suitsShort dwells, often automated overnight therapy; icodextrin for the long dwellLonger dwells with adequate volume, as in manual daytime exchanges

Icodextrin. Icodextrin is a large starch-derived molecule. It is absorbed slowly, so it keeps drawing water for many hours. It is used once a day for the long dwell: overnight in CAPD, daytime in APD. Two nursing points matter. First, it is broken down to maltose, and some bedside glucose meters and strips read maltose as glucose. The result is falsely high, and insulin given for it can cause severe hypoglycemia. Test a patient on icodextrin with a glucose-specific method, at home and in hospital, and make sure the chart carries that alert. Second, report a new rash after it is started.

Ultrafiltration failure. Some patients stay overloaded despite strong bags. Ask the practical questions first. Is salt and fluid intake high? Are exchanges being missed? Is there a drainage problem or a leak? Is urine volume falling? Is high blood sugar flattening the gradient? True membrane failure usually follows years of therapy or repeated peritonitis. By the standard definition, it is less than 400 mL of net fluid removal after a 4-hour dwell with the strongest glucose solution. Your contribution is the record that shows the trend: daily weights, bag strengths used, and drain volumes.

Remaining kidney function. Urine from the patient’s own kidneys removes salt, water, and larger waste molecules all day. In PD, keeping it is associated with better survival and easier fluid control.1 The association is observational, and patients who keep their urine may be healthier in other ways. Protecting it is still a daily nursing task, because it costs little. Watch for over-removal of fluid and dehydration, including during diarrhea or vomiting. Question nonsteroidal anti-inflammatory drugs. Make sure anyone prescribing an aminoglycoside antibiotic or ordering a contrast study knows the patient still passes urine. Ask about urine volume at every visit. A fall is a reason to review the prescription, because the dialysis must now do more.

When the record shows less fluid out than in, ask four questions: the bag, the dwell, the drain, and the diet.

Diagram of the peritoneal capillary wall with two kinds of opening, the fading glucose pull, and the shapes of fast and slow transporter curves.
Water and small solutes cross the peritoneal capillary wall through gaps between cells, and water alone crosses through tiny water-only channels. Glucose leaks back into the blood, so the pull on water fades. This happens sooner in fast transporters, which is why they do better with short dwells.

The catheter, the break-in period, and an urgent start

The PD catheter is a soft silicone tube in three parts. Inside the abdomen, a segment with many side holes lies low in the pelvis. A middle segment runs in a tunnel under the skin. The external segment ends in a connector and a transfer set. Most catheters carry two felt cuffs. The deep cuff sits in the muscle of the abdominal wall, and the superficial cuff sits under the skin a short distance from the exit site. Over several weeks tissue grows into the cuffs. That anchors the catheter and seals the track, against fluid leaking out and against organisms tracking in. The exit site is planned to point downward or sideways, away from the belt line and skin folds, where the patient can see and reach it.

Break-in. Filling the abdomen raises the pressure inside it. If full volumes are used before tissue has healed around the cuffs, fluid can leak along the catheter. A leak delays healing and invites infection. For a planned start, therapy is usually delayed about two weeks after insertion, and the catheter is flushed on the unit’s schedule meanwhile. When dialysis cannot wait, an urgent start is possible. Small fill volumes are used with the patient lying down, because pressure in the abdomen is lowest in that position. Volumes are increased gradually, and the abdomen is left empty when the patient is up and walking, as the program directs.

Early care after insertion follows the program protocol. The principles do not change:

Once the site has healed, exit-site care becomes the patient’s own routine. Hand hygiene first. Look and feel along the tunnel. Clean and dry thoroughly. Apply the prescribed topical agent. Secure the catheter.2

A catheter that never moves and a bowel that never strains give the cuffs time to seal. Protect both from the first day.

The exchange: the reason behind each step

Training teaches the steps of the system the patient uses. When you teach or audit technique, you need the reasons as well. A patient who understands why a step exists is less likely to drop it at home in the sixth month.3

PrincipleReasonWhat to look for when observing
Prepare the roomMoving air and animals carry organisms to an open connectorDoor and windows closed, fan and air conditioner off or directed away, pets out, surface wiped, everything needed within reach before starting. Contact with household pets during exchanges is a recognized peritonitis risk4
Mask, if the program requires itOrganisms from the nose and mouthCovers nose and mouth; anyone else in the room is masked or away from the field
Hand hygieneTouch is the main route of peritonitisThorough washing and, just as important, thorough drying, or alcohol hand rub, repeated if anything non-clean is touched
Check the bagThe wrong strength changes fluid removal; a damaged bag is not sterileStrength, volume, expiry date, clear fluid, firm squeeze for leaks, intact seals and caps. A doubtful bag is set aside, not used
Warm with dry heatCold fluid causes pain and shiveringA warming pad or the cycler plate; never immersion in water, which contaminates the ports. Body temperature, not hot
Connect, then drain, flush, fillSee belowConnector tips touch nothing; clamps are operated in the correct order
Inspect and measure the drainThe drained fluid is the daily test of the peritoneumClear enough to read print through the bag; pale yellow; volume by weight
RecordTrends guide the prescriptionDate, time, bag strength, volume filled, volume drained, appearance, weight, blood pressure
Disconnect and disposeThe open transfer set is again at riskNew sterile cap applied without touching the tip; fluid emptied into the toilet; bags and lines discarded as the program advises; hands cleaned

Why the flush comes before the fill. The moment of connection carries the greatest risk. In a twin-bag system the patient drains first. Then a small amount of fresh solution runs from the new bag straight into the drain bag, before any fluid goes toward the abdomen. Organisms introduced at the connection are carried away to the drain bag by the outgoing effluent and the flush. Only then is the drain line clamped and the abdomen filled. A patient who fills first, or skips the flush to save time, has removed the one design feature that makes the system forgiving.

Fluid removal. Net fluid removal for an exchange is the volume drained minus the volume filled. A positive number means water was removed. A negative number means fluid was absorbed. Units differ in how they count the small overfill in each bag and the flush volume, so the patient uses the method the program taught, every time. Report values that stay negative or keep shrinking, a rising weight, or new swelling.

Automated therapy. For APD the patient sets up the cycler in the evening. The bags are placed, the cassette and lines loaded, the machine primed, and one connection made at bedtime. The same rules about the room, the hands, and the connector tips apply, concentrated into one setup. The alarm that most often wakes patients is a drain alarm, when the machine cannot recover the expected volume. The usual causes are lying on the tubing, a kink or closed clamp, constipation, or the catheter tip resting against the pelvic wall. Teach the patient to check the line, change position, and follow the machine prompts, and to call the unit if alarms recur. Repeatedly bypassing drain alarms can leave the abdomen overfilled. Every APD household also learns manual exchanges and keeps manual supplies, so that treatment continues through a brownout or a machine fault.

When you observe an exchange, watch the hands and the connector tips. Everything else in the room exists to protect those two seconds.

Five-step twin-bag peritoneal dialysis exchange shown as labeled flow paths (connect, drain, flush, fill, disconnect), with the reason for each step and how to record net removal.
The flush comes before the fill because it carries any organisms picked up at the connection away to the drain bag before fluid flows toward the abdomen. Net fluid removal equals the volume drained minus the volume filled.

What the guidelines say

The International Society for Peritoneal Dialysis (ISPD) 2022 guideline recommends diagnosing peritonitis when at least two of three findings are present. The first is clinical features: abdominal pain, cloudy effluent, or both. The second is an effluent white cell count above 100 per microliter after a dwell of at least 2 hours, with more than 50% neutrophils. The third is a positive effluent culture.4 The guideline recommends sending effluent for cell count, differential, Gram stain, and culture whenever peritonitis is suspected. It recommends starting empirical antibiotics that cover gram-positive and gram-negative organisms as soon as the specimens are taken, preferably into the peritoneum.4 Speed matters. Peritonitis is a major reason patients leave PD for hemodialysis, and repeated or severe episodes can scar the membrane.

On training, the ISPD advises that qualified, experienced nursing staff deliver PD training from a structured curriculum. It advises reassessing technique periodically and retraining after peritonitis, after a hospital admission, or when a different person takes over the exchanges.4,3 The 2023 catheter-infection recommendations advise cleaning the exit site at least twice a week and after every shower or vigorous exercise, and applying a topical antibiotic as prescribed.2 The 2022 guideline also addresses contamination. After a break in sterile technique the patient contacts the PD unit promptly, and prophylactic antibiotics are advised when fluid has run through a contaminated, open system.4

Know how strong this evidence is. Most of the literature behind these statements is observational, and many training and exit-site practices have never been compared in randomized trials. The guidelines grade each statement. This course does not restate those grades, so read them in the guideline before quoting a statement as strong.

The ISPD prescribing recommendations ask that PD be judged by how the person feels and functions, by fluid status, and by remaining kidney function, and not by a single clearance number.1 A clearance number is a surrogate. It tells you how much urea was removed, not how the patient is living.

Infection in depth: exit site, tunnel, and peritonitis

Exit-site and tunnel infection. The ISPD defines an exit-site infection by purulent discharge at the exit site, with or without redness of the surrounding skin. A tunnel infection is inflammation along the buried track: redness, swelling, tenderness, or hardening over the catheter path, or a fluid collection seen on ultrasound.2 Redness alone can be early infection, a reaction to tape or cleanser, or the result of pulling on the catheter. Describe it and watch it closely. Many units record the exit site with a score that rates five features from 0 to 2: swelling, crust, redness, pain on pressure, and drainage. Purulent drainage counts as infection whatever the total. A score turns “looks a bit red” into something two nurses on different days can compare. When there is discharge, send a swab for culture before antibiotics start. These infections matter because the same organisms, especially Staphylococcus aureus and Pseudomonas, can travel along the catheter and cause peritonitis. An infection that does not clear can cost the patient the catheter.2

Collecting the peritonitis specimen. The first cloudy bag is the best specimen. That is why patients are told to bring it and not to discard it. If the abdomen is empty, as in an APD patient with no daytime dwell, solution is run in and left for at least 2 hours before sampling, so that the cell count can be interpreted. The effluent goes for cell count with differential, Gram stain, and culture. Inoculating fluid directly into blood-culture bottles is the preferred culture method, because it improves the chance of growing the organism.4 Label the specimen with the dwell time. Collect it before the first antibiotic dose. Do not let the wait for a result delay treatment. The Gram stain is often negative in peritonitis. Its main value is early detection of yeast.

Treatment principles. Antibiotics are preferably given into the peritoneal cavity, mixed into the dialysis bag with sterile technique, because this puts high concentrations where the infection is.4 When a dose is given once daily, the bag carrying it must dwell long enough for the drug to be absorbed. The minimum dwell is in the unit protocol. Make sure the patient understands that this bag is not drained early. Drug choice and dose belong to the prescriber and are adjusted when the culture returns. The ISPD also recommends antifungal prophylaxis whenever a PD patient receives a course of antibiotics for any reason, because antibiotics clear the way for fungal peritonitis.4 Pain is treated, constipation is prevented, and fibrin in cloudy fluid may call for heparin in the bag, if ordered.

Expected course and follow-up. Pain and cloudiness should begin to improve within about two to three days. Track symptoms and bag clarity daily. Repeat effluent cell counts confirm the fall. Three situations change the goal from saving the catheter to saving the peritoneum:

In these situations the guideline recommends removing the catheter, with temporary hemodialysis, because persisting with antibiotics risks permanent membrane damage and death.4 Patients often feel this as failure. You can frame it accurately: it protects the patient and, in many cases, the chance of returning to PD later.

Every episode is investigated. After each peritonitis the team reviews the likely cause. Was it touch contamination, an exit-site or tunnel infection, a bowel source, a recent procedure, or a change in who performs exchanges? Technique is observed again, with retraining as needed.4 Keep the tone fact-finding, not blaming. Patients who fear a scolding report late.

Unit standards. A PD program counts its infections. The ISPD 2022 targets are an overall peritonitis rate of no more than 0.40 episodes per patient-year at risk, and culture-negative peritonitis in fewer than 15% of episodes.4 A high culture-negative proportion points to a specimen problem: collection after antibiotics, too small a volume, or delayed transport. The unit corrects it with the laboratory.

Prevention around procedures. Colonoscopy and invasive gynecologic procedures can seed the peritoneum. The guideline suggests antibiotic prophylaxis beforehand and an empty abdomen during the procedure.4 Your task is communication. Teach the patient to tell the PD unit about any planned procedure. Ward and endoscopy nurses check that a plan exists. Low potassium is also associated with peritonitis, and the guideline advises avoiding and treating it.4

Specimen first, antibiotic next, cause afterward. Each step is the nurse’s to make happen, and none waits for the one before it to be perfect.

Five-step card for suspected PD peritonitis: contact the team now, assess and collect specimens, the three diagnostic criteria, prompt treatment, and reassessment.
Cloudy fluid or abdominal pain means contacting the PD team now. Peritonitis is diagnosed when at least two of three criteria are met; specimens are collected before antibiotics when feasible, and prescribed treatment starts without waiting for culture results.

Teach, observe, respond

Assess the home before training ends. Ask, and see where you can. Where will the exchanges be done? Is there a table that can be wiped clean, a place to wash and dry hands, and a door or window that closes against drafts and pets? Where will a month of boxed supplies be stored, off the floor and away from heat? How reliable are the water and electricity? Who else lives there? In the Philippines, also ask about the plan for typhoons and floods, the travel time to the PD unit, and how supplies are delivered.

Teach in small steps and confirm by return demonstration. Readiness does not mean the learner has been told, or says they understand. It means the patient or caregiver performs a complete exchange, from hand hygiene to disposal, unprompted and without a break in technique, on more than one occasion. It also means they can say what they would do if something goes wrong: a touched connector, a hole in the bag or tubing, fluid that will not drain, cloudy effluent, fever, abdominal pain, or a red or discharging exit site. If a family member will do the exchanges at home, that person is the one who demonstrates.

Respond to cloudy effluent the same day. A patient who reports cloudy fluid, with or without pain or fever, is told to come to the PD unit or emergency department today and to bring the cloudy bag. Do not advise waiting to see whether the next bag clears. Notify the PD team. Obtain the effluent specimens that are ordered. Look at the exit site and along the tunnel. Ask about recent contamination, constipation or diarrhea, and recent procedures. The antibiotics are prescribed. Your contribution is speed, a correctly collected specimen, and a fresh look at technique afterward.

For a contamination event, the first instruction is the same in every unit: stop, clamp, do not continue the exchange, and call the PD unit. What follows depends on whether fluid has already flowed through the contaminated connection. The PD team decides.

Cloudy fluid is peritonitis until tested. The bag comes with the patient, and the patient comes today.

Continue with the Peritoneal Dialysis Nurse track

This module introduces peritoneal dialysis (PD). Nurses who will work in a PD program can continue with the Peritoneal Dialysis Nurse specialty track: twelve modules over six weeks on PD physiology, home readiness, the catheter and exit site, continuous ambulatory and automated PD, goal-directed monitoring, peritonitis, urgent problems, patient teaching, transitions, special populations, and Philippine practice and quality, with skills stations and a preceptor guide.

Non-infectious complications: mechanical and metabolic

Slow or failed drainage is the most common call a PD nurse receives. First ask whether fluid moves in neither direction, or only fails to come out. Fluid that will neither fill nor drain suggests a blockage of the tube itself: a closed clamp, a kink, or a clot or fibrin plug. Fluid that fills normally but drains poorly suggests something covering the side holes, or a tip that has moved out of the pelvis: a loaded bowel, catheter migration, or omentum wrapped around the catheter. Work from the simplest cause upward:

  1. Check that all clamps are open and trace the line for kinks, including under clothing and the dressing; lower the drain bag.
  2. Change position: side to side, sitting, standing, walking.
  3. Ask about bowel movements. Constipation is the most frequent cause and is treated first, with the laxative prescribed for the patient.
  4. Look at the fluid for white strands of fibrin and report them; heparin added to the bag is by order.
  5. If drainage is still poor, the team arranges an abdominal film to see where the tip lies, and repositioning or surgery is considered only after these steps.

The patient does not keep filling an abdomen that is not draining. No one forces fluid through the catheter or pulls back hard on it.

ProblemHow it presents and whyNursing response
Pain on fillingCold or fast-flowing fluid, the acidity of standard solutions, or a catheter tip pressing on tissue; air under the diaphragm causes shoulder-tip painWarm the bag, slow the fill, prime lines fully; persistent pain is reported, and pain with cloudy fluid is peritonitis until tested
Pain at the end of drainingSuction of the catheter tip against the pelvic lining as the abdomen empties; common in the first weeksReassure, treat constipation, report; the prescriber may leave a small volume behind in automated therapy
Leak around the catheterClear fluid wetting the dressing, usually early or after strainingReport the same day; a glucose test strip on the fluid reads high because dialysis solution is rich in glucose. Therapy is usually rested or volumes reduced
Leak into tissuesSwelling of the scrotum or labia, or a soft, thickened abdominal wall, with weight gain and low drain volumes that can be mistaken for poor fluid removalReport; imaging locates the defect; many need surgical repair
Leak into the chestFluid passes through a defect in the diaphragm: breathlessness, worse lying down, low drain volumes, and a pleural effusion on one side, usually the rightUrgent report; drain the abdomen and keep the patient upright while awaiting orders
HerniaA lump at the navel, groin, or an old scar, more obvious when standing or fullReport for surgical review. A hernia that becomes painful, hard, and cannot be pushed back, especially with vomiting, is an emergency
Blood-tinged fluidPink or red fluid around menstruation or ovulation, after strenuous activity or minor trauma, or soon after catheter insertion; a little blood colors a whole bagUsually benign and clears within a few exchanges, but always reported. Heavy or persistent bleeding, pain, or dizziness needs urgent assessment

Metabolic effects. Much of the glucose in each bag is absorbed, more from stronger bags and in fast transporters. The results are higher blood sugar and greater insulin needs in diabetes, weight gain as fat, raised triglycerides, and an early feeling of fullness that blunts appetite. Your best response is to keep the patient off strong bags in the first place, by reinforcing salt restriction, and to make sure glucose testing uses a compatible meter. Low potassium is common in PD. Potassium-free solution removes it every day, and intake may be poor. It causes weakness and cramps and slows the bowel, so the diet is often liberal in potassium, and supplements may be prescribed. Protein is lost into every drained bag, and losses rise sharply during peritonitis. The recommended intake for a stable person on PD is 1.0 to 1.2 g of protein per kilogram of body weight per day.5 Many patients do not reach it without specific advice on fish, egg, chicken, and other affordable protein foods. Investigate a falling albumin. Do not just record it.

Encapsulating peritoneal sclerosis is a rare, serious, late complication. The peritoneum thickens and wraps loops of bowel in a fibrous cocoon. It appears mainly after many years of PD, sometimes only after PD has stopped. The clues are recurrent abdominal pain, vomiting and other signs of bowel obstruction, weight loss, loss of fluid removal, and blood-stained effluent. Refer a long-term patient with these symptoms promptly to the nephrologist.

For poor drainage, check the simple things in order before anyone reaches for an X-ray: clamps, position, bowel, fibrin.

Follow-up, home logistics, and the patient on a general ward

The clinic visit. Follow the same structure every time, so that nothing is missed:

Judge adequacy from the whole picture. A patient who feels well, eats, keeps weight and albumin, has no swelling, and has controlled blood pressure is being well dialyzed. A patient who is nauseated, itchy, losing weight, or overloaded is not, whatever the clearance figure says. The ISPD recommends setting the prescription through shared decisions around the person’s own goals. A smaller starting prescription is acceptable when remaining kidney function is good, with increases as it declines.1

Home logistics in the Philippines.

The PD patient admitted to a general ward. Admission is a high-risk time, because exchanges may fall to staff who have never done one.

Burnout. PD has no days off. After months or years, patients and especially caregivers tire. Steps are shortened, exchanges are skipped, records become implausibly regular, and peritonitis follows. Ask directly, and separately, how the patient and the caregiver are managing. A caregiver often will not admit strain in front of the patient. The team can offer options: a simpler prescription where clinically acceptable, training a second family member, assisted PD with a trained helper, a change between manual and automated therapy, or a planned transfer to hemodialysis. A planned transfer, discussed early with access prepared, is a treatment decision. An unplanned transfer through severe peritonitis and an emergency catheter is the outcome that honest conversation prevents.

At every visit, ask who is doing the exchanges now, and how tired they are. The answer changes more than any laboratory value.

Home hemodialysis: who, which machine, which schedule, and what is known

Peritoneal dialysis (PD) is the home therapy most nurses meet first. Home hemodialysis (HD) is a different undertaking. PD has no blood circuit and needs no treated water. Home HD takes the whole blood circuit, the needles, the water, and the alarms out of the unit and into a living room.

Every HD session carries three hazards, whatever the building. Blood runs outside the body at pump speed, so a disconnection can bleed fast. A large volume of dialysate meets the blood across a thin membrane, so the water must be clean. Fluid can be pulled from the blood faster than the tissues refill it, so blood pressure (BP) can fall. In a unit, the building and the staff contain those hazards. At home, a trained patient and care partner, a prepared house, and a program that answers the telephone at 2 a.m. must contain them instead.

Who may be suited. There is no single checklist, and each program sets its own criteria. The assessment asks the same broad questions:

Being poor, older, disabled, or living alone is not on its own a reason to say no. No household is told it is suitable before a proper home assessment.

Machine types, in general terms. Home HD machines differ mostly in how they obtain dialysate. That difference drives everything else about the home.

TypeHow dialysate is madeWhat the home must provide
Conventional-design machineMixed from concentrates and treated water, at dialysate flows similar to the unitA water-treatment system (filters, softening, carbon, and reverse osmosis) plumbed into the house, a drain, and substantial electrical capacity
Low-dialysate-volume machine with a compact water unitMade in batches or on demand by a small purification unit that connects to an ordinary tapA tap, a drain, and a standard grounded outlet; little or no permanent plumbing
Machine using prepared dialysateSupplied ready-made in bagsNo water treatment at home, but storage for large volumes of fluid and reliable deliveries

Low-dialysate-volume machines use far less fluid, so each hour is less efficient. They are usually run more often or for longer. The water standard does not relax with the smaller volume. Whatever touches the blood across the membrane must still meet dialysis quality.

Schedules. At home the prescription is no longer bound to three fixed unit shifts. The hours below are typical ranges only. The nephrologist sets the prescription for each patient.

ScheduleTypical patternWhat changes physiologicallyWhat it costs the patient
ConventionalThree sessions a week of about 4 hoursThe same as in the unit, including the long gap over the weekendFewest setups and needlings
Short dailyFive or six sessions a week of about 2 to 3 hoursSmaller fluid gains between sessions, so less fluid has to be removed each time and removal is gentler; no long gapA setup, needling, and cleanup nearly every day
NocturnalLong sessions overnight while the patient sleeps, three to six nights a weekSlow fluid removal over many hours; much more phosphate removed, because phosphate leaves the blood slowly and removal depends heavily on timeSleep beside a running machine; a care partner who may be woken; needle security becomes critical

What the trials show. The physiology predicts that more frequent or longer sessions should be better, and some measures do improve. The randomized evidence on outcomes patients feel is more modest. When you counsel a patient, know it accurately.

Registry studies in which home HD patients live longer than unit patients are explained in large part by selection. Those offered home therapy, who complete training and stay on it, tend to be younger, healthier, and better supported. A fair summary for a patient has four parts. Intensified home HD is associated with better phosphate and BP control and fewer tablets. It has not been shown to prolong life. It uses the access harder. Its strongest benefits are ones patients value directly: control over the schedule, fewer journeys, and treatment fitted around work, school, and family.

Tell patients what home HD has been shown to do, and what it has not. Better numbers and more freedom are real. Longer life has not been demonstrated.

Training a patient and care partner for home hemodialysis

Home HD training is longer and more technical than PD training. It rests on the same principle you met earlier in this module: readiness is shown, not told. The patient becomes the operator and performs the whole treatment. Where the program requires a care partner, that person must recognize trouble, stop the treatment safely, and call for help. In many programs the care partner must also be able to run the treatment if the patient cannot. Training usually takes several weeks in a dedicated area before any treatment happens at home.

Area of the curriculumWhat the trainee learns to doWhat the trainer looks for before sign-off
PrinciplesExplain how the blood circuit, dialysate, and fluid removal work, and why each safety step existsReasoning that would cover a situation the manual did not
PreparationCheck water and dialysate as their system requires, set up and prime the machine, enter the prescription exactly as writtenCorrect order of steps, without prompting, and refusal to start when a check fails
Pre-treatment assessmentWeigh, take BP and pulse, check temperature, inspect and feel the access, decide the fluid goal within the prescribed limitsRecognition of findings that mean “call before starting”: fever, a red or painful access, a weak thrill, unusual breathlessness or weight gain
CannulationHand hygiene, skin preparation, needle insertion and taping by the method the program teachesConsistent aseptic technique, secure taping, and lines that cannot be pulled out
During treatmentMonitor BP and symptoms, respond to alarms, recognize low BP and cramps earlyCorrect response to each alarm without overriding a safety alarm
EndingReturn blood, remove needles, achieve hemostasis, dispose of sharps and wasteBleeding controlled, sharps in a rigid container, no blood exposure to others in the house
Machine careDisinfection cycles, routine checks, filter changes, and logs as the manufacturer and program specifyLogs complete and plausible; knows who to call for faults
EmergenciesRespond to the situations in the table belowCorrect actions in simulated drills, including with the care partner

Teach the way you teach PD: small steps, the reason before the task, teach-back, and repeated full return demonstrations. Plan retraining after a hospital admission, a serious complication, a change of care partner, a new machine, or any sign that steps are being shortened. A nurse or technician usually attends the first treatments at home.

Self-cannulation. For most trainees, putting a needle into their own arm is the hardest step. Fear is normal. It is not a sign of unsuitability. Trainees usually begin with one needle while the nurse places the other, and progress at their own pace. Two methods are taught:

The buttonhole infection risk. The buttonhole track is a direct path from the skin into the bloodstream, and the scab over it can harbor bacteria. A home HD cohort study with a systematic review found buttonhole cannulation associated with more access infection than rope-ladder, without fewer surgical procedures on the fistula.9 That is observational evidence, and units using buttonholes may differ in other ways. A second systematic review found that the evidence does not support preferring buttonhole over rope-ladder, in the unit or at home. It noted that buttonhole may suit some patients whose fistulas are hard to needle.10 Where a program uses buttonholes, the technique must be exact every time: hand hygiene, skin cleaning, scab removal with a sterile device without digging, cleaning again, and a new sterile needle. Teach patients to report redness, swelling, pus, or pain at a site, and fever or chills during or after treatment, the same day. Treat chills during a session in a buttonhole patient as a possible bloodstream infection until assessed.

Water and electricity at home. You do not certify a home. You do need to know what must be in place, so that you recognize when something has changed.

Emergencies at home. The specific steps come from the program and the manufacturer, and patients practice them in drills. The principles are fixed:

EventFirst actions taughtThen
Needle dislodgement or bleeding from a needle siteStop the blood pump, clamp the lines, press firmly on the siteCall the program; call an ambulance for heavy bleeding or faintness. Taping that leaves the needle sites visible, and moisture sensors where the program uses them, reduce the risk at night
Low BP: dizziness, yawning, nausea, crampsStop fluid removal, lie flat with legs raised, give fluid only as the program’s written instructions directRecheck BP; call if it does not recover or symptoms persist; record the event for prescription review
Air or blood-leak alarmNever override; follow the machine prompts and stop if the cause is not clearCall the program; do not restart a treatment the program has not cleared
Chest pain, severe breathlessness, collapseStop treatment as trained and call an ambulanceThe care partner starts basic life support if trained and needed
Fever or chills during treatmentStop treatment as trainedCall the program the same day; possible access or bloodstream infection, or a water problem
Power failureReturn blood manually or disconnect as trained for that machineReport the incomplete treatment; the program arranges a backup session

Remote monitoring. Many programs receive treatment data from the home, sent by the machine or entered by the patient: weights, BP readings, fluid removed, treatment time, and alarms. A home program nurse reviews them against agreed triggers, such as shortened or missed treatments, rising weights, repeated low BP, or frequent alarms, and contacts the patient early. Monitoring supports care. It does not replace a response team, clinic visits, or laboratory tests. Health data sent from a home is personal information, and its collection, storage, and access must follow the Philippine Data Privacy Act.11 As in PD, shortened sessions and implausibly perfect records are signs of fatigue. Ask the patient and care partner separately how they are coping, and offer respite sessions in the unit.

At home, the patient is the operator and you are the safety net. Make sure every person in the house knows how to stop the blood pump and press on a bleeding site.

Home hemodialysis training pathway: eight curriculum areas with sign-off, home water, drainage, and electricity checks, first treatments at home with a nurse, remote monitoring triggers, and retraining triggers that loop back.
Readiness is shown, not told: the trainee performs the whole treatment, and the care partner can recognize trouble, stop safely, and call. Any change in the house, the machine, the care partner, or the patient's health sends the pathway back to training.

Home hemodialysis in the Philippines: what is real today

Patients hear about home HD online, from relatives abroad, or from people selling machines. You are often the first person they ask.

Home PD and home HD are not in the same position. Home PD is an established service with a defined national benefit route, as this module described earlier. For home HD, this site’s review of published national insurer and regulatory documents did not locate a dedicated home HD benefit package or a published national licensing standard for treatment in a private home. (See the assigned reading on home hemodialysis in the Philippines.) The national insurer’s outpatient HD benefit is written around treatments in licensed dialysis centers. No public national count of patients on home HD was located. These are statements about what was found in published documents. They are not proof that nothing exists. Confirm the current rules with the Philippine Health Insurance Corporation, the Department of Health, and the nephrologist before any decision.

What a household would have to carry. In a unit, the facility pays for and maintains the water plant, the generator, the technicians, and the stock room. At home those become separate costs. Unless a program or insurer covers them, they fall on the family:

Household realities. Many Filipino homes are crowded, rented, or informal. They cannot easily give up a room, a drain, or a grounded circuit. Brownouts, typhoons, and floods interrupt water, power, and deliveries, sometimes for days. Care partners usually also work, or care for children and elders. None of this makes home HD impossible. It means a safe service has to be built around the household, not simply installed in it.

Your part, today.

A machine is not a program. Home HD is safe only when tested water, trained people, a night-time response, and a backup chair come with it.

Case: Ready to go home?

Mr. Alfredo Santiago, 64, started CAPD two weeks ago. His wife, Aling Nena, will do his exchanges because his eyesight is poor. During training Mr. Alfredo answered every question correctly. The couple want to go home to their province, six hours away. Aling Nena has watched four exchanges but has performed only part of one.

Three weeks after discharge, at nine in the evening, she telephones you. Tonight’s drain bag looks “like rice-washing water,” and he has mild abdominal pain.

Before reading on, decide what you would assess, what you would communicate and to whom, what you would teach, and what would make you escalate. Then compare with the outline below.

Assess

Before discharge: who will actually perform exchanges; home space, water, electricity, storage; Aling Nena’s complete, unprompted technique and her responses to warning signs. On the call: effluent appearance, pain, fever, exit site, any contamination, bowel habit.

Communicate

Before discharge: tell the PD team that the operator has not completed a full return demonstration. On the call: notify the PD nephrologist immediately of suspected peritonitis and the travel time.

Teach

On the call: do not wait; bring the cloudy bag; where to go tonight (the nearest hospital able to send effluent tests and start treatment, as arranged by the PD team).

Escalate

Severe pain, vomiting, high fever, or low blood pressure: emergency department without delay.
Documentation task. Write a readiness checklist of six observable behaviors you would need to see from Aling Nena before signing off training.

Check your understanding

Each visit draws 5 questions at random from this module’s 18-question bank, in a shuffled order. Choose the single best answer for each, then select Check answers; a rationale appears under every option. Reload the page or select New set of questions for a different mix. Nothing you select is sent anywhere; scoring happens in your browser.

Question 1 of 18A patient on peritoneal dialysis telephones to report that his drained fluid is cloudy and he has abdominal pain. What should the nurse advise?
Question 2 of 18In peritoneal dialysis, what is the dwell?
Question 3 of 18A caregiver will perform all exchanges at home. She has watched several and answered questions correctly. What is required before training is signed off?
Question 4 of 18Mr. Ramon, 58, has been on CAPD for two months. He reports that for the past two days his bags fill normally but drain slowly and incompletely. The fluid is clear, he has no pain or fever, and he has not moved his bowels for four days. What should the nurse do first?
Question 5 of 18A caregiver telephones the PD unit. She has drained the old fluid and was about to flush and fill when the open end of the new bag’s connector brushed against her sleeve. No fresh fluid has run yet. What is the correct instruction?
Question 6 of 18A patient on nocturnal home HD telephones the program at 3 a.m. His wife woke to find the bed wet with blood near his venous needle, and the machine is alarming. He is awake and talking. What should the nurse instruct first?
Question 7 of 18At a unit meeting, a colleague says: "The trials proved that nocturnal home HD makes patients live longer, so everyone who can should switch." Which response best reflects the evidence?
Question 8 of 18Mr. Ernesto, 52, on in-center HD, tells the nurse that a supplier has offered to sell him a home machine. He plans to use water from the refilling station his family drinks from, have his son needle him, and come to the unit only "if something goes wrong." What is the best response?
Question 9 of 18A patient on peritoneal dialysis asks why the nurse keeps saying that a very long dwell with a standard glucose bag can leave him with less fluid out than he put in. Which explanation is correct?
Question 10 of 18Mrs. Teresita has just started automated peritoneal dialysis (APD) with a cycler at night. She asks why the nurse still insists that she and her son learn to do manual exchanges and keep manual supplies at home. What is the best answer?
Question 11 of 18A PD patient with diabetes who uses icodextrin for the long dwell is admitted to a general ward. The bedside meter reading before dinner is much higher than her usual values, and a correctional insulin scale has been ordered. She looks well. What should the nurse do before giving insulin?
Question 12 of 18At a clinic visit, Mr. Celso, who has been on PD for six months and still passes a good amount of urine each day, says he has been buying an over-the-counter anti-inflammatory pain reliever for knee pain. What is the most appropriate nursing response?
Question 13 of 18During a home visit, a nurse observes a twin-bag exchange. After draining, the patient clamps the drain line and fills his abdomen at once, explaining that the flush “just wastes fluid.” What is the key teaching point?
Question 14 of 18A PD patient’s home record for the past five days shows that the volume drained is consistently smaller than the volume filled. His weight has risen and his ankles are swollen. How should the nurse interpret and act on this record?
Question 15 of 18A nurse observing a new PD patient at home notes that he plans to do his exchanges in a room with an electric fan running toward the table and the family cat asleep on a chair nearby. Which instruction best addresses the risk?
Question 16 of 18At a PD clinic visit, the nurse removes the dressing and finds yellow, purulent discharge at the exit site with surrounding redness. The patient has no abdominal pain and his effluent is clear. What should the nurse do?
Question 17 of 18Mrs. Lourdes, on CAPD for three months, reports increasing breathlessness that is worse when she lies down. Her drain volumes have been low for several days, and a chest film shows fluid on the right side. Her effluent is clear. What is the priority nursing action?
Question 18 of 18A patient on CAPD is admitted to a general medical ward with pneumonia. None of the ward nurses has been trained in PD exchanges, and the patient is too unwell to do his own. What should the admitting nurse do first about his dialysis?
Reflect. If a PD patient were admitted to your ward tonight for an unrelated reason, who would perform the exchanges, and would that person be able to do one without contaminating the system?

What this module builds

Milestone. After this module, the nurse can judge whether a PD patient or caregiver is safe to go home, by observing a full return demonstration and responding urgently to contamination and cloudy effluent.

Each competency names an observable ability, the level this module aims for, and how that level is confirmed. Levels follow Miller’s pyramid. Self-study reaches knows; the higher levels are reached only when an educator or preceptor verifies them, and they are recorded on the competency checklist.

CompetencyThreadTarget levelVerified by
Relates transport type, glucose strength, and dwell length to the PD prescription, compares CAPD with APD, and explains why remaining kidney function is protected.Delivering kidney replacement therapyKnowsSelf-assessment, Nursing case
Describes the drain, fill, and dwell phases while observing an exchange, and states the reason for each step, including flush before fill and recording net fluid removal.Delivering kidney replacement therapyDoes, supervisedObserved practice
Performs hand hygiene and a twin-bag connection, in simulation or under supervision, without touching connector tips, and names the routes by which organisms reach the peritoneum.Infection prevention and controlDoes, supervisedObserved practice
Inspects a PD exit site and tunnel, describes the findings in the unit’s standard terms or score, and reports discharge, redness, or tenderness the same day.Vascular and peritoneal accessDoes, supervisedObserved practice
Rehearses the peritonitis specimen workflow: keeps the first cloudy bag, confirms the dwell time, labels the specimen, and sends it before the first antibiotic dose.Infection prevention and controlShows howSimulation, Skills station
Collects, or simulates collection of, a PD effluent specimen exactly as the unit directs and as ordered, with correct labeling and prompt dispatch.Infection prevention and controlDoes, supervisedObserved practice
Gives the first instruction for a contamination event (stop, clamp, call the PD unit) and for cloudy effluent (same-day assessment, bring the bag), and notifies the PD team.Recognizing deterioration and emergency responseDoes, supervisedObserved practice
Teaches a complete PD exchange on a training model and confirms by teach-back the learner’s responses to contamination, cloudy effluent, poor drainage, and exit-site changes.Patient and family teaching, nutrition, and shared decisionsShows howSkills station, Teach-back
Observes a patient or caregiver return demonstration, identifies any break in technique, and reports whether home readiness meets the PD program’s sign-off criteria.Patient and family teaching, nutrition, and shared decisionsDoes, supervisedObserved practice
Recognizes non-infectious PD complications, such as leaks, hernia, and blood-tinged effluent, and applies the stepwise response to poor drainage before reporting.Clinical assessment and fluid statusKnowsSelf-assessment, Nursing case
Explains peritonitis treatment principles and follow-up, and the ward care of a PD patient, including notifying the dialysis team and glucose-specific testing with icodextrin.Medicines and their safetyKnowsSelf-assessment, Nursing case
Performs the routine PD clinic review of weight, blood pressure, swelling, urine volume, and home exchange records after sign-off, and reports deviations to the PD team.Clinical assessment and fluid statusDoes, independentObserved practice, Record review
Teaches one part of the home hemodialysis curriculum to a simulated patient and care partner, giving the reason for each step, and confirms competence by full return demonstration rather than by attendance.Patient and family teaching, nutrition, and shared decisionsShows howSimulation, Teach-back
Explains rope-ladder and buttonhole self-cannulation, states the higher infection risk associated with buttonholes and the aseptic steps that buttonhole use requires, and teaches the access signs a patient must report the same day.Vascular and peritoneal accessShows howSkills station, Teach-back
Rehearses with a simulated patient and care partner the home response to needle dislodgement, low blood pressure, a safety alarm, fever or chills, and a power failure during treatment, including when to call the program and when to call an ambulance.Recognizing deterioration and emergency responseShows howSimulation
Counsels a patient who asks about home hemodialysis accurately on its evidence, the requirements for water, support, and backup, and its uncertain availability and coverage in the Philippines, refers the question to the nephrologist, and includes home peritoneal dialysis as an option.Professional, ethical, and legal practiceShows howSimulation, Nursing case

With your preceptor

Observational exposure with a PD nurse where a program exists; otherwise simulation with a training apron or mannequin. These are prompts for supervised learning, not a procedure. Your preceptor observes and signs off each item on the unit’s own competency form; the educator page has a printable version.

Read next on this site

Glossary & abbreviationsTalahulugan at mga daglatTalaan sa mga pulong ug daglatTalatinigan ampo reng daglat terms used on this page

Abbreviations

APD
Automated peritoneal dialysis — Exchanges performed by a cycler machine, usually overnight.
CAPD
Continuous ambulatory peritoneal dialysis — Manual exchanges several times a day.
HD
Hemodialysis.
ISPD
International Society for Peritoneal Dialysis.
PD
Peritoneal dialysis.

Terms

Peritoneum
The membrane lining the abdominal cavity and covering the abdominal organs.
Effluent
Used dialysis fluid drained from the abdomen.
Exit site
The point where the PD catheter leaves the skin.
Cycler
The machine that performs automated exchanges.
Return demonstration
The learner performs the whole skill while the teacher observes.
Peritoneal equilibration test
A standardized 4-hour dwell with timed samples that shows how quickly solutes and glucose cross the peritoneal membrane.
Transport type
The classification of a peritoneal membrane from fast to slow according to the equilibration test.
Icodextrin
A starch-derived osmotic agent that is absorbed slowly and is used for one long dwell each day.
Ultrafiltration failure
Inability of the peritoneal membrane to remove enough water despite appropriate solutions.
Break-in period
The healing time between catheter insertion and the start of full-volume exchanges.
Transfer set
The short extension tube between the catheter and the dialysis bag system, changed at intervals by the PD unit.
Flush before fill
Running a small amount of fresh solution to the drain bag before filling, to wash away organisms introduced at connection.
Refractory peritonitis
Peritonitis in which the effluent fails to clear after 5 days of appropriate antibiotics.
Relapsing peritonitis
Peritonitis returning within 4 weeks of completing treatment with the same organism or with no growth.
Encapsulating peritoneal sclerosis
A rare late complication in which a thickened peritoneum encases the bowel and causes obstruction.
Home hemodialysis
Hemodialysis performed in the patient’s home by a trained patient and care partner, supported by a dialysis program.
Care partner
A trained person, usually a family member, who supports or performs home dialysis and responds to emergencies.
Assisted home dialysis
Home dialysis in which a paid, trained helper performs or supports the treatment.
Short daily hemodialysis
Five or six shorter sessions a week in place of three standard sessions.
Nocturnal hemodialysis
Long, slow hemodialysis sessions performed overnight while the patient sleeps.
Low-dialysate-volume machine
A hemodialysis machine that uses much less dialysate per session and is usually run more often or for longer.
Rope-ladder cannulation
Rotating needle sites along the whole length of a fistula.
Buttonhole cannulation
Inserting blunt needles into the same tunnel track at each session; associated with higher access infection rates.
Remote monitoring
Review by the program of treatment data sent from the home, against agreed triggers for contact.
ReferencesMga SanggunianMga TinubdanReng Reperensya 13 sources
  1. Brown, E. A., Blake, P. G., Boudville, N., Davies, S., de Arteaga, J., Dong, J., Finkelstein, F., Foo, M., Hurst, H., Johnson, D. W., Johnson, M., Liew, A., Moraes, T., Perl, J., Shroff, R., Teitelbaum, I., Wang, A. Y., & Warady, B. (2020). International Society for Peritoneal Dialysis practice recommendations: Prescribing high-quality goal-directed peritoneal dialysis. Peritoneal Dialysis International, 40(3), 244–253. https://doi.org/10.1177/0896860819895364
  2. Chow, K. M., Li, P. K., Cho, Y., Abu-Alfa, A., Bavanandan, S., Brown, E. A., Cullis, B., Edwards, D., Ethier, I., Hurst, H., Ito, Y., de Moraes, T. P., Morelle, J., Runnegar, N., Saxena, A., So, S. W., Tian, N., & Johnson, D. W. (2023). ISPD catheter-related infection recommendations: 2023 update. Peritoneal Dialysis International, 43(3), 201–219. https://doi.org/10.1177/08968608231172740
  3. Figueiredo, A. E., Bernardini, J., Bowes, E., Hiramatsu, M., Price, V., Su, C., Walker, R., & Brunier, G. (2016). A syllabus for teaching peritoneal dialysis to patients and caregivers. Peritoneal Dialysis International, 36(6), 592–605. https://doi.org/10.3747/pdi.2015.00277
  4. Li, P. K., Chow, K. M., Cho, Y., Fan, S., Figueiredo, A. E., Harris, T., Kanjanabuch, T., Kim, Y. L., Madero, M., Malyszko, J., Mehrotra, R., Okpechi, I. G., Perl, J., Piraino, B., Runnegar, N., Teitelbaum, I., Wong, J. K., Yu, X., & Johnson, D. W. (2022). ISPD peritonitis guideline recommendations: 2022 update on prevention and treatment. Peritoneal Dialysis International, 42(2), 110–153. https://doi.org/10.1177/08968608221080586
  5. Ikizler, T. A., Burrowes, J. D., Byham-Gray, L. D., Campbell, K. L., Carrero, J. J., Chan, W., Fouque, D., Friedman, A. N., Ghaddar, S., Goldstein-Fuchs, D. J., Kaysen, G. A., Kopple, J. D., Teta, D., Yee-Moon Wang, A., & Cuppari, L. (2020). KDOQI clinical practice guideline for nutrition in CKD: 2020 update. American Journal of Kidney Diseases, 76(3, Suppl. 1), S1–S107. https://doi.org/10.1053/j.ajkd.2020.05.006
  6. FHN Trial Group, Chertow, G. M., Levin, N. W., Beck, G. J., Depner, T. A., Eggers, P. W., Gassman, J. J., Gorodetskaya, I., Greene, T., James, S., Larive, B., Lindsay, R. M., Mehta, R. L., Miller, B., Ornt, D. B., Rajagopalan, S., Rastogi, A., Rocco, M. V., Schiller, B., ... Kliger, A. S. (2010). In-center hemodialysis six times per week versus three times per week. The New England Journal of Medicine, 363(24), 2287–2300. https://doi.org/10.1056/NEJMoa1001593
  7. Rocco, M. V., Lockridge RS Jr, Beck, G. J., Eggers, P. W., Gassman, J. J., Greene, T., Larive, B., Chan, C. T., Chertow, G. M., Copland, M., Hoy, C. D., Lindsay, R. M., Levin, N. W., Ornt, D. B., Pierratos, A., Pipkin, M. F., Rajagopalan, S., Stokes, J. B., Unruh, M. L., ... Kwok, S. (2011). The effects of frequent nocturnal home hemodialysis: the Frequent Hemodialysis Network Nocturnal Trial. Kidney International, 80(10), 1080–1091. https://doi.org/10.1038/ki.2011.213
  8. Rocco, M. V., Daugirdas, J. T., Greene, T., Lockridge, R. S., Chan, C., Pierratos, A., Lindsay, R., Larive, B., Chertow, G. M., Beck, G. J., Eggers, P. W., Kliger, A. S., & FHN Trial Group. (2015). Long-term effects of frequent nocturnal hemodialysis on mortality: The Frequent Hemodialysis Network (FHN) Nocturnal Trial. American Journal of Kidney Diseases, 66(3), 459–468. https://doi.org/10.1053/j.ajkd.2015.02.331
  9. Muir, C. A., Kotwal, S. S., Hawley, C. M., Polkinghorne, K., Gallagher, M. P., Snelling, P., & Jardine, M. J. (2014). Buttonhole cannulation and clinical outcomes in a home hemodialysis cohort and systematic review. Clinical Journal of the American Society of Nephrology, 9(1), 110–119. https://doi.org/10.2215/CJN.03930413
  10. Wong, B., Muneer, M., Wiebe, N., Storie, D., Shurraw, S., Pannu, N., Klarenbach, S., Grudzinski, A., Nesrallah, G., & Pauly, R. P. (2014). Buttonhole versus rope-ladder cannulation of arteriovenous fistulas for hemodialysis: a systematic review. American Journal of Kidney Diseases, 64(6), 918–936. https://doi.org/10.1053/j.ajkd.2014.06.018
  11. National Privacy Commission (NPC). (2012). Republic Act No. 10173: Data Privacy Act of 2012. https://privacy.gov.ph/data-privacy-act/
  12. Van Waeleghem, J. P., Chamney, M., Lindley, E. J., & Pancírová, J. (2008). Venous needle dislodgement: how to minimise the risks. Journal of Renal Care, 34(4), 163–168. https://doi.org/10.1111/j.1755-6686.2008.00047.x
  13. International Organization for Standardization (ISO). (2024). Preparation and quality management of fluids for haemodialysis and related therapies — Part 5: Quality of dialysis fluid for haemodialysis and related therapies (ISO 23500-5:2024). https://www.iso.org/standard/84372.html
Dr. William Gregory M. Rivero, MD

William Gregory Rivero, MD, FPCP, DPSN

Internal Medicine · Nephrology · Nutrition · Philippines · PRC 0105184

Educational self-study for registered nurses. Does not replace physician orders, approved unit procedures, manufacturer instructions, DOH licensing requirements, or supervised clinical training.

QR code — scan to save Dr. Rivero's contact info

Scan and save