- Measure the inferior vena cava (IVC) diameter in centimeters.
- If it is 2 cm or more, classify the hepatic vein, portal vein and intrarenal vein Doppler patterns as normal, mildly abnormal or severely abnormal.
- Read the Venous Excess Ultrasound (VExUS) grade and the rule that produced it. A pattern you could not obtain stays "not obtained".
For clinicians trained in point-of-care Doppler. All computation runs in your browser; nothing is stored or sent.
When to Use
Use it to document a VExUS grade in a patient in whom venous congestion would change management, such as heart failure with rising creatinine or the period after cardiac surgery. The grade describes an ultrasound phenotype: how much the venous Doppler signals are distorted by raised right-sided pressure.
Setting decides how much the grade means
In the 145-patient cardiac surgery derivation cohort, grade 3 was associated with later acute kidney injury (AKI) (hazard ratio 3.69, 95% CI 1.65 to 8.24). In a 145-patient general intensive care cohort, admission VExUS was not associated with AKI (p = 0.136). A 2026 meta-analysis of 32 studies found the same split: an association in cardiac patients (odds ratio 4.44, 95% CI 2.34 to 8.43) and none in the critically ill (odds ratio 1.45, 95% CI 0.70 to 2.99).
Pearls & Pitfalls
Read the grade with the bedside picture
Combine it with the examination, lung ultrasound, cardiac function, urine output and the fluid balance trend. A falling grade over serial studies is more informative than one value.
When the waveforms mislead
Cirrhosis and portal hypertension alter portal and hepatic flow without venous congestion. Severe tricuspid regurgitation reverses the hepatic systolic wave by itself. Positive-pressure ventilation, raised intra-abdominal pressure, arrhythmia, chronic kidney disease and poor acoustic windows all limit interpretation. Record a pattern as "not obtained" when the tracing is inadequate.
What trials show so far
In a 140-patient randomized trial in cardiorenal syndrome type 1, VExUS-guided decongestion did not improve kidney function recovery, though more patients were decongested. An 80-patient pilot trial in AKI showed that a randomized trial of ultrasound-guided fluid assessment is feasible; it found no difference in AKI progression. No trial has shown that acting on the grade improves patient-important outcomes.
VExUS Grading Worksheet
Enter what was measured. For the portal vein, either choose a category or type the pulsatility fraction; a typed percentage takes priority.
Enter the IVC diameter to begin.
⚕ Documents the original VExUS grade from operator-classified findings. It gives no AKI probability and no diuretic or fluid recommendation.
Evidence & References
The grade combines vena cava diameter with three venous Doppler patterns. It describes congestion; it is not a probability of kidney injury.
- VExUS
- Venous Excess Ultrasound
- IVC
- Inferior vena cava
- AKI
- Acute kidney injury
Grading table (original VExUS C system)
| Grade | Definition |
|---|---|
| 0 | IVC under 2 cm |
| 1 | IVC 2 cm or more, with normal or mildly abnormal Doppler patterns only |
| 2 | IVC 2 cm or more, with one severely abnormal pattern |
| 3 | IVC 2 cm or more, with two or more severely abnormal patterns |
| Vein | Normal | Mild | Severe |
|---|---|---|---|
| Hepatic | S larger than D | S smaller than D | S reversed |
| Portal | Pulsatility under 30% | 30% to under 50% | 50% or more |
| Intrarenal | Continuous | Discontinuous, two phases | Discontinuous, diastolic only |
Incomplete data. A definitive grade is shown only where the rule already settles it: IVC under 2 cm (grade 0), or two severe patterns (grade 3). Otherwise the worksheet states a lower bound and marks the study incomplete.
References
- Beaubien-Souligny W, Rola P, Haycock K, et al. Quantifying systemic congestion with point-of-care ultrasound: development of the venous excess ultrasound grading system. Ultrasound J. 2020;12(1):16. doi:10.1186/s13089-020-00163-w
- Andrei S, Bahr PA, Nguyen M, Bouhemad B, Guinot PG. Prevalence of systemic venous congestion assessed by Venous Excess Ultrasound Grading System (VExUS) and association with acute kidney injury in a general ICU cohort: a prospective multicentric study. Crit Care. 2023;27(1):224. doi:10.1186/s13054-023-04524-4
- Klompmaker P, Opschoor K, Dalen JT, et al. Diagnostic and prognostic value of the Venous Excess Ultrasound Grading System (VExUS): a systematic review and meta-analysis. Crit Care Med. 2026;54(9):2419-2429. doi:10.1097/CCM.0000000000007219
- Islas-Rodríguez JP, Miranda-Aquino T, Romero-González G, et al. Effect on kidney function recovery guiding decongestion with VExUS in patients with cardiorenal syndrome 1: a randomized control trial. Cardiorenal Med. 2024;14(1):1-11. doi:10.1159/000535641
- Gouin M, Huard K, Shen A, et al. A pilot randomized controlled trial of ultrasound evaluation of fluid tolerance for acute kidney injury: USE-the-FORCE-for-AKI trial. Clin J Am Soc Nephrol. 2026;21(7):1126-1134. doi:10.2215/CJN.0000001059