- Honest rate: enter how many cases were eligible, how many you excluded and why, and how many met the standard. Use it for hand hygiene, referral closure, teach-back, records accuracy or corrective actions.
- Infection rate: enter bloodstream infections and patient-months for each access type separately. One patient treated for a whole month is one patient-month.
- Treatment delivery: enter pre- and post-dialysis urea from a valid sample pair, the prescribed and delivered minutes, and the fluid removed with the post-dialysis weight.
- Hemoglobin trend: enter two results with their dates.
- Nothing you enter is stored or sent. Use fictional or de-identified numbers for practice.
When to Use
Use these tools for portfolio work: monthly audits, the quality meeting, an infection review, an adequacy review, or an anemia trend that needs to reach the prescriber. They make the arithmetic and the denominators visible so that the unit can act on honest numbers.
When NOT to rely on it
This toolkit never recommends a dose, a prescription change, a target weight or a treatment time. A hemoglobin fall with bleeding symptoms, an access with no thrill, or a patient who is unwell needs the physician now, not a calculation. Urea reduction ratio is a surrogate measure; Kt/V by your unit’s method and the patient’s symptoms, fluid status and goals matter as much.
Honest rate
A percentage is only as honest as its denominator. Record exclusions openly; never drop the hard cases to make the number look better.
⚕ The 95% range (Wilson score interval) shows how much a small count can bounce by chance. Show results month by month on a run chart before calling a change real.
Bloodstream infection rate by access type
Rates are per 100 patient-months, calculated separately for each access type, because catheters carry a much higher risk than fistulas. Mixing them hides where the problem is.
⚕ Use one written definition of a bloodstream infection and count every positive blood culture event the same way each month. With small numbers, one infection moves the rate a lot; look at the events themselves, not only the rate.
Treatment-delivery check
Was the treatment delivered as prescribed? Validity first, then the numbers.
⚕ For thrice-weekly treatment, the 2015 KDOQI guideline targets a single-pool Kt/V of 1.4 with a delivered minimum of 1.2; a urea reduction ratio of 65% corresponds roughly to a Kt/V of 1.2. A higher dose did not lower mortality in the HEMO trial, so adequacy is a floor, not a dial. Ultrafiltration rates above 13 mL/kg/h were associated with higher mortality in an observational analysis. The physician decides any change.
Hemoglobin trend
How fast is hemoglobin moving? Speed matters as much as the level.
⚕ This tool only describes the trend. Epoetin product labels advise prescriber review when hemoglobin rises by more than 1 g/dL in any 2-week period. A falling hemoglobin with bleeding symptoms is a clinical problem for the physician today, not a step on a dosing protocol.
Evidence & References
Formula & Equations
| Quantity | Equation or rule |
|---|---|
| Honest rate | Numerator ÷ (eligible − excluded) × 100, with a 95% Wilson score interval; exclusions shown beside the result |
| Infection rate | Bloodstream infections ÷ patient-months × 100, per access type and overall |
| Urea reduction ratio | (Pre − post) ÷ pre × 100 |
| Time delivered | Delivered minutes ÷ prescribed minutes × 100 |
| Ultrafiltration rate | Fluid removed (mL) ÷ post-dialysis weight (kg) ÷ delivered hours |
| Hemoglobin pace | (Latest − earlier) ÷ days between × 7 |
Evidence
Run charts display a measure in time order and use simple run rules to separate signal from noise. In a CDC collaborative of 17 outpatient hemodialysis facilities, audits with feedback, catheter-care training and chlorhexidine exit-site care were followed by modeled falls of 32% in bloodstream infections and 54% in access-related bloodstream infections; the project had no control group. The KDOQI 2015 adequacy guideline sets a target single-pool Kt/V of 1.4 for thrice-weekly hemodialysis with a minimum delivered dose of 1.2. In the HEMO trial, a higher dose did not reduce mortality. In an analysis of HEMO participants, ultrafiltration rates above 13 mL/kg/h were associated with higher all-cause and cardiovascular mortality. The KDIGO 2026 anemia guideline frames treatment as an individual decision weighing symptoms and risks.