1 · Urea reduction ratio and single-pool Kt/V
Module 03
Formula. URR = (pre − post) ÷ pre. spKt/V (Daugirdas second generation) = −ln(R − 0.008 × t) + (4 − 3.5 × R) × UF ÷ W, where R = post ÷ pre. Teaching floor: spKt/V 1.2 minimum delivered, 1.4 target for thrice-weekly sessions (KDOQI 2015; confirm against unit policy). Check first: a post sample drawn without the slow-flow or stop-dialysate method gives a falsely good result.
2 · Ultrafiltration rate
Modules 02, 07, 09
Formula. mL ÷ hours ÷ kg. Flags: above 10 mL/h/kg risk begins to rise; above 13 was associated with 59% higher mortality in HEMO Study data (Flythe 2011, observational). No trial has shown that capping the rate saves lives. Flag for the prescriber; do not change the order.
3 · Interdialytic weight gain
Module 02
Formula. (pre today − post last) ÷ target weight. Gain to remove today = pre today − target. Use: compare with the patient's own usual gain, and look at breathing, not just the scale. A patient who has lost flesh is overloaded at an unchanged target.
4 · Opening gates and staffing
Modules 01, 08
Rule. DOH AO 2012-0001 sets one nurse per four stations and at least one nurse per shift with updated ACLS. Confirm locally how stations are counted. Only nurses with site sign-off count. Which patients can be deferred is the nephrologist's decision.
5 · Audit result with a 95% confidence interval
Modules 05, 11
Method. Wilson score interval. The width shows how much the result could move by chance. Aim for at least 30 observations before comparing months.
6 · Infection rate and catheter dependence
Modules 04, 05
Formulas. Events ÷ patient-months × 100. Catheter infections ÷ catheter-days × 1,000. Reference points: a Philippine single-center cohort reported 6.72 per 1,000 catheter-days (Pasilan 2024). Use the same case definition every month or the trend is meaningless.
7 · Blood-loss clock
Module 04
Why it matters. In a bench simulation the venous pressure alarm missed 11 of 19 needle dislodgments (Frinak 2023). Only an uncovered, visible access is a reliable detector. Blood volume is estimated at 70 mL/kg for teaching.
8 · Water checks: reverse-osmosis rejection and carbon contact time
Module 06
Formulas. Rejection = (1 − product ÷ feed) × 100. Empty-bed contact time = bed volume ÷ flow. Teaching flags: the expected rejection comes from your RO manufacturer and SOP, and the trend matters more than one value; carbon contact time at least 10 minutes in total at peak flow, at least 5 minutes in each of two tanks in series (AAMI-based requirements, 42 CFR 494.40). Your SOP's adopted limits govern. Release decisions belong to the designated authority.
9 · PhilHealth session tracker
Module 10
Rules verified 23 November 2026: up to 156 sessions per calendar year at PHP 6,350 (effective 9 October 2024); unused sessions do not carry over. Confirm with billing before advising a patient.
10 · Run-chart helper
Module 11
Rules applied. Shift: six or more consecutive points on one side of the median (points on the median are skipped). Trend: five or more consecutive points all rising or all falling. Rate shown as percent. Always read with the denominators.
11 · Disaster triage list
Module 12
Logic. Sorted by symptoms, then days since last session, then potassium. Flags: symptoms, 3 or more days since treatment, or last potassium above 6.0 (teaching flag; unit protocol governs). This list is a prompt for the physician's prioritization, not the prioritization itself.
12 · Delivered time
Modules 03, 09
Why. Time drives clearance and sets how fast fluid must come off. An average can hide a few sessions that lose 30 minutes or more. This tool lists them.
13 · Roster size and rest check
Module 13 (also 08)
Formula. Nurses per shift = stations ÷ stations per nurse, rounded up. Nurse-shifts = nurses per shift × shifts per day × days. Full-time nurses = nurse-shifts ÷ shifts per nurse. Payroll = full-time nurses × relief factor, rounded up. Relief factor from records = scheduled days ÷ (scheduled days − days away). ACLS cover is a separate requirement on every shift. The 11-hour rest line comes from research on quick returns, not from a Philippine regulation; your employer’s rule governs.