- Enter the number of accesses created in the audit cohort and how many were lost to follow-up before the outcome window closed.
- Enter primary failures (never usable or failed before use) and the number used successfully for dialysis within your stated window, both counted among those followed up.
- Optionally enter interventions and access-years at risk, and catheter-days with catheter-related bloodstream infections (CRBSI).
- Define the cohort, window and censoring rules before collecting data, and report them with the results.
All computation runs in your browser; no values are stored or transmitted. Educational tool written for the Renal Care Academy Vascular Surgeon track; clinical review pending.
When to Use
Use for a service audit, a quality meeting or a capstone service proposal, when you need numbers that can be compared over time without hiding missing data or small-number uncertainty.
Definitions first
Rates per 1,000 catheter-days and NHSN rates per 100 patient-months are different measures. Do not compare across definitions or across services with different case mix.
Pearls & Pitfalls
Technical is not functional
Report patency and functional use separately. A patent fistula that is never used is a failure for the patient.
Pitfalls
Dropping patients lost to follow-up flatters results. Small services see wide intervals: one event can move a rate dramatically, so show counts.
Why Use It
The SVS reporting standards define patency so results can be compared. Honest audits state their denominator, show uncertainty and missing data, and point to a change the team can test.
AV Access Outcome Audit
Next Steps
- Pick one gap the numbers expose, such as unused mature fistulas or long catheter exposure.
- Define one process change and one measure, and set a review date.
- Plot the measure monthly on a run chart.
Evidence & References
Formula and rules
| Quantity | Rule |
|---|---|
| Primary failure | failures ÷ (created − lost); exact Clopper–Pearson 95% CI |
| Functional use | used ÷ (created − lost); best case adds all lost as used, worst case counts them as not used |
| Intervention rate | interventions ÷ access-years; exact Poisson 95% CI |
| CRBSI rate | events ÷ catheter-days × 1,000; exact Poisson 95% CI |
References
- Sidawy, A. N., Gray, R., Besarab, A., Henry, M., Ascher, E., Silva, M., Miller, A., Scher, L., Trerotola, S., Gregory, R. T., Rutherford, R. B., & Kent, K. C. (2002). Recommended standards for reports dealing with arteriovenous hemodialysis accesses. Journal of Vascular Surgery, 35(3), 603–610. https://doi.org/10.1067/mva.2002.122025
- Aitken, E., Anijeet, H., Ashby, D., Barrow, W., Calder, F., Dowds, B., Fielding, C., Gilbert, J., Jones, R., Karunanithy, N., Khawaja, Z., Roberts, E., Robson, M., Shroff, R., Stacey, H., Thomson, P., & Waters, D. (2025). UK Kidney Association clinical practice guideline on vascular access for haemodialysis. BMC Nephrology, 26(1), 461. https://doi.org/10.1186/s12882-025-04374-y
- Al-Jaishi, A. A., Oliver, M. J., Thomas, S. M., Lok, C. E., Zhang, J. C., Garg, A. X., Kosa, S. D., Quinn, R. R., & Moist, L. M. (2014). Patency rates of the arteriovenous fistula for hemodialysis: A systematic review and meta-analysis. American Journal of Kidney Diseases, 63(3), 464–478. https://doi.org/10.1053/j.ajkd.2013.08.023
- Huber, T. S., Berceli, S. A., Scali, S. T., Neal, D., Anderson, E. M., Allon, M., Cheung, A. K., Dember, L. M., Himmelfarb, J., Roy-Chaudhury, P., Vazquez, M. A., Alpers, C. E., Robbin, M. L., Imrey, P. B., Beck, G. J., Farber, A. M., Kaufman, J. S., Kraiss, L. W., Vongpatanasin, W., . . . Feldman, H. I. (2021). Arteriovenous fistula maturation, functional patency, and intervention rates. JAMA Surgery, 156(12), 1111–1118. https://doi.org/10.1001/jamasurg.2021.4527